ABOUT THIS MANUAL
This booklet is an integral and essential part of the product and
should be handed over to the operator after the installation and
preserved for any further consultation that may be necessary.
Please read carefully the guidelines and warnings contained
herein as they are intended to provide the user with essential
information for the continued safe use and maintenance of the
product. In addition, it provides GUIDANCE ONLY to the user on
the correct services and site location of the unit.

IMPORTANT SAFETY INSTRUCTIONS

! Intended Use

The dispenser is for indoor use only. This unit is not a toy. Children should not be supervised not to play with appliance. It should
with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety. Cleaning and user maintenance
shall not be performed by children without supervision. The min/max ambient operating temperature for the dispenser is 40°F to
personnel. Applicable safety precautions must be observed. Instruction warnings on the product being used must be followed.
®
4500
Ice Dispenser 22" - Model 4400
BEFORE GETTING STARTED
Each unit is tested under operating conditions and is thoroughly
inspected before shipment. At the time of shipment, the carrier
accepts responsibility for the unit. Upon receiving the unit,
carefully inspect the carton for visible damage. If damage exists,
claim with carrier. Responsibility for damage to the dispenser lies
with the carrier.
LANCER INSTALLATION GUIDE
Revision: September 2018
Lancer PN: 28-3008

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4400 and is the answer not in the manual?

Questions and answers

Summary of Contents for lancer 4400

  • Page 1: Important Safety Instructions

    Ice Dispenser 22” - Model 4400 LANCER INSTALLATION GUIDE ABOUT THIS MANUAL BEFORE GETTING STARTED This booklet is an integral and essential part of the product and Each unit is tested under operating conditions and is thoroughly should be handed over to the operator after the installation and inspected before shipment.
  • Page 2: Specifications

    ! Water Notice standards. It is the responsibility of the installer to ensure compliance. ! Automatic Agitation without assistance. For heavier dispensers, use a mechanical lift. SPECIFICATIONS ID 4400 - 22” Cubed Ice DIMENSIONS ELECTRICAL WEIGHT Width Shipping...
  • Page 3: Installation

    NOTE NOTE If unit is to be transported, it is advisable to leave the Lancer does NOT recommend the use of shaved or unit secured to the plywood shipping base. Remove accessory kit and loose parts from ice compartment. In order to facilitate proper dispenser drainage, ensure that NOTE the dispenser is level, front to back and side to side.
  • Page 4: Dispenser Installation

    Route the power supply cord to a grounded electrical outlet Contact your icemaker manufacturer to obtain the correct bin of the proper voltage and connect to outlet. thermostat. ! WARNING edge of the dispenser. The preferred location of the bin The dispenser must be properly electrically grounded thermostat is on the left side wall.
  • Page 5: Cleaning And Sanitizing

    CLEANING AND SANITIZING GENERAL INFORMATION Lancer equipment (new or reconditioned) is shipped from the factory cleaned and sanitized in accordance with NSF guidelines. The operator of the equipment must provide continuous maintenance as required by this manual and/or state and local health department guidelines to ensure proper operation and sanitation requirements are maintained.
  • Page 6: Troubleshooting

    Ice Chute Cleaning - Monthly NOTE NOTE Always remove the ice chute lever before removing the splash plate. It is recommended to perform this procedure monthly, or more often if desired. Use the cleaning solution described above. An alternate solution of one part Remove the Ice Chute Assembly base by removing the four water to one part vinegar may be used to remove water spots and calcium deposits.
  • Page 7 Automatic Agitation and Low Ice Alarm Control NOTE is provided to control the timing and low ice control. Dispensers using pellet ice must have the automatic agitation DIP# DESCRIPTION position. Switch Number Switch # Agitation Off Time Agitation On Time No Agitation 10 Minutes 40 Minutes...
  • Page 8 ILLUSTRATIONS & PART LISTINGS NOTE: Final Assembly - ID 4400 Cubed Ice TO ADJUST ICE FLOW REGULATOR, SEE PAGE 4 (230 VOLT ONLY) Item Part No. Description...
  • Page 9 Pellet Ice Dispenser Sub-Assembly Conversion Kit, IBD22, PN: 82-3955 F ATTENTION The Pellet Ice Components listed below are to be used ONLY in conjunction with Nugget, Cubelet, or Chewblet ice. LANCER Item Part No. Description LABEL FOR SCOTSMAN LABEL FOR HOSHIZAKI...
  • Page 10: Dispenser Disposal

    T&S Water Valve Assembly Dispenser Disposal To prevent possible harm to the environment from improper disposal, recycle the unit purchased. Comply with local regulations regarding disposal of the refrigerant and insulation.
  • Page 11 Wiring Diagram - 115 Volt / 60 Hz NOT USED ON NOTE: PREMIX DISPENSERS ELECTRICAL BOX BOUNDARY WHITE BLACK LIGHT VALVE BLACK ALARM WHITE BLUE WHITE LOW ICE SENSOR LOW ICE SENSOR EMITTER DETECTOR BLACK DISPENSE SWITCH WHITE GREEN BLACK TRAP BLACK DOOR...
  • Page 12 Lancer Corp. custserv@lancercorp.com lancercorp.com...