ADJUSTING WATER FLOW AND WATER TO SYRUP RATIO (BRIX)......22 CARBONATOR PUMP MODIFICATIONS................23 4. TROUBLESHOOTING......................24-29 5. ILLUSTRATIONS, PARTS LISTINGS, AND WIRING DIAGRAMS FINAL ASSEMBLY......................30-31 ICE CHUTE ASSEMBLY......................32 PELLET ICE ASSEMBLY AND PARTS LISTING..............33 LANCER FLOW CONTROL VALVE (LFCV)...............34 WIRING DIAGRAM......................35 PLUMBING DIAGRAM WITH VALVE WIRING..............36 FS30COUNTER CUTOUT....................37...
Installation and Operation Manual PN 28-0580/03 ABOUT THE FS30 The FS30 is designed using the highest quality materials and state-of-the-art technology providing our customers with consistent quality and a unique drink experience. FS30 SPECIFICATIONS 26 1/2” (673 mm) 30” (762 mm) 14 5/8”...
Flavor Select (FS) 22 Ice Beverage Dispenser PRE-INSTALLATION CHECKLIST BEFORE GETTING STARTED Each unit is tested under operating conditions and is thoroughly inspected before shipment. At the time of shipment, the carrier accepts responsibility for the unit. Upon receiv- ing the unit, carefully inspect the carton for visible damage. If damage exists, have the car- rier note the damage on the freight bill and file a claim with carrier.
Installation and Operation Manual PN 28-0580/03 WARNING/ADVERTENCIA/AVERTISSEMENT The dispenser is for indoor use only. This appliance is intended for use in commercial applications such as res- taurants, stores or similar. This unit is not a toy. It should not be used by children or infirm persons without supervi- sion.
Page 6
Flavor Select (FS) 22 Ice Beverage Dispenser ELECTRICAL WARNING/ADVERTENCIA ELéCTRICA/ AVERTISSEMENT ÉLECTRIQUE Check the dispenser serial number plate for correct electrical requirements of unit. Do not plug into a wall electri- cal outlet unless the current shown on the serial number plate agrees with local current available. Follow all local electrical codes when making connections.
Page 7
L’installateur est responsable d'assurer la conformité. ICE INFORMATION Dispensers using cubed ice may also use pellet ice if properly configured. Contact Lancer Customer Service or your Sales Representative for more information.Lancer dispensers will not dispense shaved or flaked ice. Do use bagged ice.
Flavor Select (FS) 22 Ice Beverage Dispenser 1. INSTALLATION BEFORE GETTING STARTED Each unit is tested under operating conditions and is thoroughly inspected before shipment. At the time of shipment, the carrier accepts responsibility for the unit. Upon receiving the unit, carefully inspect the carton for visible damage.
B. Sufficient clearance must be provided, if an ice maker is not installed, to allow filling the ice compartment from a five gallon bucket (a minimum of 16 inches (106.4 mm) is recommended), refer to Fig 3. Lancer does NOT recommend the use of shaved or flake ice in the dispenser.
B. An adapter plate is required when installing an icemaker. Contact your Sales Representative or Lancer Customer Service for more information. C. A bin thermostat is required in order to control the level of ice in the dispenser (Refer to WARNING below).
If the static water pressure exceeds 50 PSI (0.345 MPA), install a water regulator before the carbonator water inlet. The Lancer Water Booster/Tank (PN MC-163172) is offered as a kit. The water booster must be installed as close as possible to the plain water circuit inlet.
C. Connect the plain water supply line and the water supply for the carbonator to the 3/8 inch barb fittings at the front of the unit. NOTE: Install the water regulator (Lancer PN 18-0306) as close as possible to the water carbonator pump inlet. Refer to Figure 6.
Page 15
Installation and Operation Manual PN 28-0580/03 1.10 INSTALLING THE FS30 DISPENSER, CONTINUED Install the cup rest and splash plate. Connect the power cord to a grounded electrical outlet. ! AGITATION WARNING THE BIN AGITATION SYSTEM WILL OPERATE AUTOMATICALLY. DO NOT PLACE HANDS IN THE BIN OR THE ICE CHUTE.
If other equipment is being cleaned, follow the guide lines established by the manufacturer for that equipment. B. Lancer equipment (new or reconditioned) is shipped from the factory cleaned and sanitized in accordance with NSF guidelines. The equipment must be cleaned and sanitized after installation is complete.
E. Fill a cup with clean warm water and rinse nozzle body. Make certain that the nozzle o-ring is not torn or otherwise damaged. If necessary, replace damaged o-ring with Lancer PN 02-0231. G. Wet the inner surface of the nozzle housing with water and reinstall the nozzle housing by sliding it over the nozzle body and turning clockwise to lock in position.
Page 18
Flavor Select (FS) 22 Ice Beverage Dispenser G. WHITE WHEEL SHROUD (PELLET ICE) G. BLACK WHEEL SHROUD (CUBED ICE) Remove the gasket which secures the shroud by Remove the dispensing wheel shroud. pulling it out. Push the front section of the shroud back. Remove the lower ice chute assembly.
Installation and Operation Manual PN 28-0580/03 CLEANING AND SANITIZING BEVERAGE COMPONENTS - BAG-IN-BOX SYSTEMS NOTE: Extended lengths of product lines may require more time to flush and rinse lines. A. Disconnect the syrup quick disconnect coupling from the syrup packages and connect the coupling to a bag valve removed from an empty Bag-in-Box (BIB) package.
E. Top off cup as desired. PROGRAMMING AND SETUP SOFTWARE NOTE: Lancer reserves the right to make changes and updates as required. If you have any questions regarding the latest versions of programs, please contact your Lancer representative. The Lancer FS22 has been factory preset to the settings necessary to comply with the brand/flavor version of the unit requested by the customer.
Page 21
Installation and Operation Manual PN 28-0580/03 MENUS AND SUBMENUS Bonus Flavors a. Decide if the bonus flavors will be set to add an injected flavor to the brands or dispense carbonated water/plain water. b. Choose the Valve number (1-4) by scrolling UP and DOWN arrows. c.
Activate dispensing valve to fill separator syrup tube. G. Hold a Lancer brix cup under the syrup separator and dispense water and syrup into cup for four seconds. Divide number of ounces of water in cup by four to determine water flow rate per second.
Installation and Operation Manual PN 28-0580/03 CARBONATOR PUMP MODIFICATIONS The electric, positive displacement rotary vane pump with 170 PSI bypass should only be serviced by trained personnel. To achieve optimum carbonation, use filtered water with the pump. A. Turn off power to the dispenser. B.
Flavor Select (FS) 22 Ice Beverage Dispenser 4. TROUBLESHOOTING TROUBLE CAUSE REMEDY 4.1 No product when switch is A. Keyswitch is off, or keyswitch A. Turn keyswitch on and/or activated. (Switch panel does not harness is disconnected. reconnect keyswitch harness. light up when activated.) B.
Page 25
Installation and Operation Manual PN 28-0580/03 TROUBLE CAUSE REMEDY 4.7 Valves do not operate. A. Keyswitch is off, or keyswitch A. Turn keyswitch and/or make harness is disconnected. sure keyswitch harness is con- nected. B. Circuit breaker tripped. B. Reset circuit breaker. C.
Page 26
Flavor Select (FS) 22 Ice Beverage Dispenser TROUBLE CAUSE REMEDY 4.14 Insufficient syrup flow. A. Insufficient CO2 pressure to A. Adjust CO2 pressure to 80 PSI, BIB pumps. 5.5 bar (min 70 PSI, 4.8 bar) for BIB pumps. B. Shutoff on mounting block not B.
Page 27
Installation and Operation Manual PN 28-0580/03 TROUBLE CAUSE REMEDY 4.17 Valve will not shut off. A. Debris in solenoid seat. A. Activate valve a few times to free debris. Remove the solenoid coil and plunger and clean out foreign material. B.
Page 28
Flavor Select (FS) 22 Ice Beverage Dispenser TROUBLE CAUSE REMEDY 4.22 Circuit breaker tripping. A. Valve wire harnesses shorted A. Detect short by disconnecting to itself or faucet plate. valve harnesses from switch panel (2 25-pin harnesses and 2 9-pin harnesses).
Page 29
Installation and Operation Manual PN 28-0580/03 TROUBLE CAUSE REMEDY 4.26 BIB pump fails to restart after A. BIB connector not on tight. A. Tighten BIB connector. bag replacement. B. BIB connector is stopped up. B. Clean out or replace BIB connector.
Installation and Operation Manual PN 28-0580/03 5.3 PELLET ICE ASSEMBLY AND PARTS LISTING Use the components listed on this page with pellet ice only. Item Part No. Description 05-2325/01 Ice Shroud, IC 23-1401/01 Agitator Assy, Helical, IC 10-0762 Pin, Hex Design, FS-16 03-0368 Retainer, Pin, Agitator, IBD 82-3651...
Installation and Operation Manual PN 28-0580/03 5.7 FS22 COUNTER CUTOUT FS30 COUNTER CUTOUT 30” 15/16” 28 1/8” 23” 18 5/8” 15” 30 1/2” 11 1/2” 3“ DIAMETER OPTIONAL 1 1/2” 3“ F R O N T D I S P E N S E R 1 5/8”...
Page 38
LANCER To order parts, call Customer Service: 800-729-1500 Warranty: 800-729-1550 Email: custserv@lancercorp.com www.lancercorp.com...