lancer 2200 Series Installation Manual

Ice cooled drop-in
Hide thumbs Also See for 2200 Series:

Advertisement

Quick Links

FOR QUALIFIED INSTALLER ONLY. This basic Installation Sheet is an initial release. If a complete
Operations Manual (for the unit being installed) is required or needed, please refer to the Lancer web
site (lancercorp.com) for immediate access, or for your convenience, scan this QR code with a mobile
device (app required) for immediate access to other Technical Documents and alternative translations
(if available) pertaining to this unit. Contact Lancer Customer Service for assistance as required.
ABOUT THIS MANUAL
This booklet is an integral and essential part of the product and
should be handed over to the operator after the installation and
preserved for any further consultation that may be necessary.
Please read carefully the guidelines and warnings contained
herein as they are intended to provide the user with essential
information for the continued safe use and maintenance of the
product. In addition, it provides GUIDANCE ONLY to the user on
the correct services and site location of the unit.
The installation and relocation, if necessary, of this product must be carried out by qualified personnel with
up-to-date safety and hygiene knowledge and practical experience, in accordance with current regulations.
IMPORTANT SAFETY INSTRUCTIONS
! Intended Use
The dispenser is for indoor use only. This unit is not a toy. Children should not be supervised not to play with appliance. It should
not be used by children or infirm persons without supervision. This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety. Cleaning and user maintenance
shall not be performed by children without supervision. The min/max ambient operating temperature for the dispenser is 40°F to
90°F (4°C to 32°C). Do not operate unit below minimum ambient operation conditions. Should freezing occur, cease operation of
the unit and contact authorized service technician. Service, cleaning and sanitizing should be accomplished only by trained
personnel. Applicable safety precautions must be observed. Instruction warnings on the product being used must be followed.
F Electrical Warning
Check the dispenser name plate label, located behind the splash plate, for the correct electrical requirements of unit.
into a wall electrical outlet unless the current shown on the serial number plate agrees with local current available. Follow all local
electrical codes when making connections. Each dispenser must have a separate electrical circuit. Do not use extension cords with
this unit. Do not 'gang' together with other electrical devices on the same outlet. The keyswitch does not disable the line voltage to
the transformer primary. Always disconnect electrical power to the unit to prevent personal injury before attempting any internal
maintenance. The resettable breaker switch should not be used as a substitute for unplugging the dispenser from the power source
to service the unit. Only qualified personnel should service internal components of electrical control housing. Make sure that all
water lines are tight and units are dry before making any electrical connections!
5 Carbon Dioxide (CO
WARNING:
Carbon Dioxide (CO2) is a colorless, noncombustible gas with a light pungent odor. High percentages of CO
displace oxygen in the blood.
Prolonged exposure to CO
WARNING:
tremors which are followed by a loss of consciousness and suffocation.
If a CO
gas leak is suspected, immediately ventilate the contaminated area before attempting to repair the leak.
WARNING:
2
WARNING:
Strict attention must be observed in the prevention of CO
®
2200, 2300
23300, 2400
)
2
can be harmful. Personnel exposed to high concentrations of CO
2
Ice Cooled Drop-In
Series: 2200, 2300, 23300, & 2400
LANCER INSTALLATION GUIDE
BEFORE GETTING STARTED
Each unit is tested under operating conditions and is thoroughly
inspected before shipment. At the time of shipment, the carrier
accepts responsibility for the unit. Upon receiving the unit,
carefully inspect the carton for visible damage. If damage exists,
have the carrier note the damage on the freight bill and file a
claim with carrier. Responsibility for damage to the dispenser lies
with the carrier.
gas leaks in the entire CO
2
Do not plug
may
2
gas will experience
2
and soft drink system.
2
LANCER PN: 28-0484/05
Revision: September 2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2200 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for lancer 2200 Series

  • Page 1 FOR QUALIFIED INSTALLER ONLY. This basic Installation Sheet is an initial release. If a complete Operations Manual (for the unit being installed) is required or needed, please refer to the Lancer web site (lancercorp.com) for immediate access, or for your convenience, scan this QR code with a mobile device (app required) for immediate access to other Technical Documents and alternative translations (if available) pertaining to this unit.
  • Page 2: Specifications

    ! Water Notice Provide an adequate potable water supply. Water pipe connections and fixtures directly connected to a potable water supply must be sized, installed, and maintained according to federal, state, and local laws. The water supply line must be at least a 3/8 inches (9.525 mm) pipe with a minimum of 25 psi (0.172 MPa) line pressure, but not exceeding a maximum of 50 psi (0.345 MPa).
  • Page 3: Read This Manual

    READ THIS MANUAL This manual was developed by the Lancer Corporation as a reference for the owner/operator and installer of this dispenser. Please read this guide before installation and operation of this dispenser. If service is required please call your Lancer Service Agent or Lancer Customer Service.
  • Page 4: Dispenser Installation

    23 inches (58.42 cm) below the counter, which The installation, and relocation if necessary, must Lancer recommends be left attached to the unit. Should be carried out by qualified personnel with up-to-date the dispenser ever require removal, the shipping risers knowledge and practical experience, in accordance with will protect the inlet tubes from being damaged.
  • Page 5: Dispenser Setup

    Installing CO Supply Using a wrench, loosen lock nut on the regulator adjustment screw of the high pressure CO regulator connected to the Connect high pressure CO regulator assembly to CO source, then using a screwdriver back out lock nut screw all cylinder or bulk system.
  • Page 6: Adjust Water Flow Rate & Syrup/Water Ratio

    10. Turn on CO at the source then, using a screwdriver, adjust Using a Lancer ratio cup verify water flow rate (5 oz. in 4 the high pressure regulator at the source to 110 psi (0.758 sec.). Use a screwdriver to adjust if needed.
  • Page 7: General Information

    CLEANING AND SANITIZING GENERAL INFORMATION Lancer equipment (new or reconditioned) is shipped from the factory cleaned and sanitized in accordance with NSF guidelines. The operator of the equipment must provide continuous maintenance as required by this manual and/or state and local health department guidelines to ensure proper operation and sanitation requirements are maintained.
  • Page 8: Plumbing Diagrams

    Cleaning and Sanitizing Syrup Lines - Bag in Box Cleaning and Sanitizing Ice Bin Compartment NOTE Disconnect syrup lines from BIB’s Place syrup lines, with BIB connectors, in a bucket of warm The ice bin compartment of the dispenser should be water.
  • Page 9 2200, 6 Valve, (3-2-1) 2300, 6 Valve, High Performance 2300, 8 Valve, Standard 2300, 8 Valve, High Performance...
  • Page 10 2300, 10 Valve, Standard 2300, 10 Valve, High Performance...
  • Page 11: Wiring Diagrams

    Key Switch Key Switch Orientation Left On Right On Bottom Lancer PN: 06-4039 LEFT BANK OF VALVES CENTER BANK OF VALVES RIGHT BANK OF VALVES Dispenser Disposal To prevent possible harm to the environment from improper disposal, recycle the unit by locating an authorized recycler or contact the retailer where the product was purchased.
  • Page 12 Lancer Corp. 800-729-1500 Technical Support/Warranty: 800-729-1550 custserv@lancercorp.com lancercorp.com...

This manual is also suitable for:

2300 series23300 series2400 series

Table of Contents