b. Sensitivity:   R ange   [ 1-­‐100].   T he   v alue   o f   t he   s ensitivity   d efines   t he   s ize   o f   t he   o bject   w hich  
can   t rigger   t he   a larm,   w hen   t he   s ensitivity   i s   h igh,   a   v ery   s mall   o bject   c an   t rigger   t he  
alarm.      
c.
Percentage:   R ange   [ 1-­‐100].   P ercentage   d efines   t he   r atio   o f   t he   i n-­‐region   p art   o f   t he   o bject  
which   c an   t rigger   t he   a larm.   F or   e xample,   w hen   y ou   s et   t he   p ercentage   a s   5 0%,   h alf   o f   t he  
object   e ntering   t he   r egion   w ill   t rigger   t he   a larm.    
Arming   S chedule   i s   c onfigured   t o   s et   t he   t ime   y ou   w ant   t he   f unction   t o   a uto-­‐enable.    
4) Click   E dit   t o   s et   t he   a rming   s chedule.    
5) Choose   t o   t rigger   a larm   a ctions   a s   N otify   S urveillance   C enter,   S end   E mail,   U pload   t o   F TP   a nd  
Trigger   C hannel   o r   t rigger   t he   A larm   O utput.      
6) Click   S ave   t o   s ave   t he   s ettings.      
CONFIGURING   D EFOCUS   D ETECTION    
Purpose:    
The   i mage   b lur   c aused   b y   d efocus   o f   t he   l ens   c an   b e   d etected   a nd   a   s eries   o f   a larm   a ction   c an   b e   t riggered.      
Steps:    
1) Check   t he   E nable   D efocus   D etection   c heckbox.      
2) Choose   t o   t rigger   a larm   a ctions   a s   N otify   S urveillance   C enter   a nd   S end   E mail,   o r   t rigger   t he   A larm  
Output.      
3) Click   S ave   t o   s ave   t he   s ettings.    
CONFIGURING   S CENE   C HANGE   D ETECTION    
Purpose:    
Scene   c hange   d etection   i s   u sed   t o   d etect   t he   c hange   o f   s urveillance   e nvironment   a ffected   b y   t he   e xternal  
factors;   s uch   a s   t he   i ntentional   r otation   o f   t he   c amera.      
Steps:    
1) Check   t he   E nable   S cene   C hange   D etection   c heckbox.      
Sensitivity:   R ange   [ 1%-­‐100%].   T he   h igher   t he   s ensitivity,   t he   e asier   t he   c hange   o f   s cene   c an   t rigger  
the   a larm.      
Arming   S chedule   i s   c onfigured   t o   s et   t he   t ime   y ou   w ant   t he   f unction   t o   b e   e nabled.    
2) Click   E dit   t o   s et   t he   a rming   s chedule.    
3) Choose   t o   t rigger   a larm   a ctions   a s   N otify   S urveillance   C enter   a nd   S end   E mail,   o r   t rigger   t he   A larm  
Output.      
4) Click   S ave   t o   s ave   t he   s ettings.      
 