b. Sensitivity:
R ange
[ 1-‐100].
T he
v alue
o f
t he
s ensitivity
d efines
t he
s ize
o f
t he
o bject
w hich
can
t rigger
t he
a larm,
w hen
t he
s ensitivity
i s
h igh,
a
v ery
s mall
o bject
c an
t rigger
t he
alarm.
c.
Percentage:
R ange
[ 1-‐100].
P ercentage
d efines
t he
r atio
o f
t he
i n-‐region
p art
o f
t he
o bject
which
c an
t rigger
t he
a larm.
F or
e xample,
w hen
y ou
s et
t he
p ercentage
a s
5 0%,
h alf
o f
t he
object
e ntering
t he
r egion
w ill
t rigger
t he
a larm.
Arming
S chedule
i s
c onfigured
t o
s et
t he
t ime
y ou
w ant
t he
f unction
t o
a uto-‐enable.
4) Click
E dit
t o
s et
t he
a rming
s chedule.
5) Choose
t o
t rigger
a larm
a ctions
a s
N otify
S urveillance
C enter,
S end
E mail,
U pload
t o
F TP
a nd
Trigger
C hannel
o r
t rigger
t he
A larm
O utput.
6) Click
S ave
t o
s ave
t he
s ettings.
CONFIGURING
D EFOCUS
D ETECTION
Purpose:
The
i mage
b lur
c aused
b y
d efocus
o f
t he
l ens
c an
b e
d etected
a nd
a
s eries
o f
a larm
a ction
c an
b e
t riggered.
Steps:
1) Check
t he
E nable
D efocus
D etection
c heckbox.
2) Choose
t o
t rigger
a larm
a ctions
a s
N otify
S urveillance
C enter
a nd
S end
E mail,
o r
t rigger
t he
A larm
Output.
3) Click
S ave
t o
s ave
t he
s ettings.
CONFIGURING
S CENE
C HANGE
D ETECTION
Purpose:
Scene
c hange
d etection
i s
u sed
t o
d etect
t he
c hange
o f
s urveillance
e nvironment
a ffected
b y
t he
e xternal
factors;
s uch
a s
t he
i ntentional
r otation
o f
t he
c amera.
Steps:
1) Check
t he
E nable
S cene
C hange
D etection
c heckbox.
Sensitivity:
R ange
[ 1%-‐100%].
T he
h igher
t he
s ensitivity,
t he
e asier
t he
c hange
o f
s cene
c an
t rigger
the
a larm.
Arming
S chedule
i s
c onfigured
t o
s et
t he
t ime
y ou
w ant
t he
f unction
t o
b e
e nabled.
2) Click
E dit
t o
s et
t he
a rming
s chedule.
3) Choose
t o
t rigger
a larm
a ctions
a s
N otify
S urveillance
C enter
a nd
S end
E mail,
o r
t rigger
t he
A larm
Output.
4) Click
S ave
t o
s ave
t he
s ettings.
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
Configuring
D efocus
D etection
Figure 6-‐47
User Manual| VISIX
N etwork
C amera
61