10.8 RS-‐485
S ettings
Purpose:
The
R S-‐485
s erial
p ort
i s
u sed
t o
c ontrol
t he
P TZ
o f
t he
c amera.
T he
c onfiguring
o f
t he
P TZ
p arameters
should
b e
d one
b efore
y ou
c ontrol
t he
P TZ
u nit.
Steps:
1) Enter
R S-‐485
P ort
S etting
i nterface:
Configuration>
A dvanced
C onfiguration>
S ystem
>
R S485
2)
Set
t he
R S-‐485
p arameters
a nd
c lick
S ave
t o
s ave
t he
s ettings.
By
d efault,
t he
B aud
R ate
i s
s et
a s
9 600
b ps,
t he
D ata
B it
i s
8 ,
t he
s top
b it
i s
1
a nd
t he
P arity
a nd
Flow
C ontrol
i s
N one.
Note:
T he
B aud
R ate,
P TZ
P rotocol
a nd
P TZ
A ddress
p arameters
s hould
b e
e xactly
t he
s ame
a s
t he
PTZ
c amera
p arameters.