To mount the access point on a wall using the provided template:
1. Xerox copy the template (on the previous page) to a blank piece of paper. Do not reduce or
enlarge the scale of the template.
CAUTION
2. Tape the template to the wall mounting surface.
• If the installation requires the antenna be positioned vertically, the centerline reference (of
the template) needs to be positioned vertically. The cabling shall exit the access point in a
vertical direction.
• If the installation requires the antenna be positioned horizontally, the vertical centerline (of
the template) needs to be positioned horizontally. The cabling shall exit the access point in
a horizontal direction.
3. At mounting targets A and B, mark the mounting surface through the template at the target
center.
4. Discard the mounting template.
5. At each point, drill a hole in the wall, insert an anchor, screw into the anchor the wall
mounting screw and stop when there is 1mm between the screw head and the wall.
6. If pre-drilling a hole, the recommended hole size is 2.8mm (0.11in.) if the screws are going
directly into the wall and 6mm (0.23in.) if wall anchors are being used.
7. If required, install and attach a security cable to the access point lock port.
8. Attach the antennas to their correct connectors.
9. For information on available antennas, see Antenna Options on page 6.
10. Place the large center opening of each of the mount slots over the screw heads.
If printing the mounting template (on the previous page) from an
electronic PDF, dimensionally confirm the template by measuring each
value for accuracy.