Power states

The server has the following power states:
Standby power
Full power
Off
Table 2 Power states
Power states
Standby power
Full power
Off
CAUTION:
power must be completely removed from the server. You can do this by switching off the circuit
breakers that are part of the building installation, disconnecting or switching off a power distribution
unit, or by physically removing the power cords from the server.
Be aware that removing AC power from the server for an extended period can drain the system
battery.
NOTE:
If the power restore feature is set to Always On through the iLO 3 MP PR command, the
server automatically powers on to the full power state when the power cord is plugged in to the
server.

Applying standby power to the server

1.
Plug the power cord into the receptacle in power supply.
2.
Plug the other end of the power cord into an AC outlet.
NOTE:
LED is green when the server is powered on to full power.
If the power restore feature is set to Always On through the iLO 3 MP PR command, the server
automatically powers on to the full power state when the power cord is plugged into the server.
3.
If the server has two power supplies, plug the second power cord into the power supply.
4.
Plug the other end of the power cord into an AC outlet.

Connecting to the LAN

The server has four LAN ports that provide network connectivity.
1.
Obtain valid IP addresses for each LAN port you plan to activate.
2.
Connect the LAN cable from an available LAN port into a live connection on the network.

Setting up the system

For more information on using the iLO 3 MP, see the HP Integrity iLO 3 Operations Guide.

Setup checklist

Use the checklist in
Power cable
Power activated through the iLO 3 PC
plugged into
command; or front panel power button
receptacle?
activated?
Yes
No
Yes
Yes
No
No
If the server is expected to remain in standby mode for more than 30 minutes, AC
The LED on the power supply does not illuminate in the standby power state. The
Table 3
while setting up the Integrity iLO 3.
Standby DC
DC voltage
voltage applied?
applied?
Yes
No
Yes
Yes
No
No
Setting up the system