At Engine Stop
When the stop lever of the governor lever 3 (7) is
moved to the stop position, the governor lever 2 (1) is
activated to move the governor lever 1 (2) in the
direction of arrow D. The control rack (3) is now moved
to the stop position (no fuel injection), thereby stopping
the engine.
It should be noted that the fuel injection limit pin and
the maximum speed adjust bolt have been factory
adjusted with a proper maximum power output in
consideration. They should never be readjusted.