For the Service Technician
4.5.1 Values
The following values are displayed:
Temp. Boiler
The current boiler temperature is displayed in °C.
Temp. chamb.
The current temperature in the combustion chamber is dis-
played in °C.
Fan speed
The nominal speed of the blower is displayed in rpm.
Pos. Prim. airfl.
The position of the primary air choke is displayed in %.
Pos. Sec. airfl.
The position of the secondary air choke is displayed in %.
O2 signal
The O2 signal of the lambda sensor is displayed in %.
O2 heat current
The O2 heat current of the lambda sensor is displayed in A.
Temp. Exhaust
The current flue gas temperature is displayed in °C.
4.5.2 Restart temperature
The blower switches off if the boiler temperature is too high. The restart tem-
perature is the temperature at which the blower switches back on and the boil-
er resumes normal heating operation.
Factory setting: 75 °C
Possible settings: 65 °C or 75 °C
4.5.3 Burnout
– automatic detection
Burnout characteristics are determined by MES thermal distribution mod-
ule WVF .
If only "Solid fuel operation" is set on the WVF , "Burnout" with embers
maintenance is undertaken. With all other settings on the WVF , a normal
burnout is undertaken.
– normal
A normal burnout is always undertaken, i.e. the wood is burnt as best as
possible until no more remains without embers maintenance.
– Embers maintenance
Burnout with embers maintenance is always undertaken, i.e. basic embers
are maintained to make it easier to light up again.
Factory setting: normal
29
Temp. Boiler
Temp. chamb.
Fan speed
2150 rpm
Pos. Prim. airfl.
Pos. Sec. airfl.
O2 signal
Back
Fig. 63
O2 heat current
Temp. Exhaust
Fig. 64
Back
Boiler temperature
for restart
75
Save
6 6 5 5
Yes
No
Fig. 65
Burnout
automatic detection
normal
Embers maintenance
Save
Yes
No
Fig. 66
68°C
578°C
60%
30%
18.1%
2.5A
195°C
°C