3.4.1.2
Single-controller RAID to Single-controller
JBODs
The single-controller model, S12F-G1433, can connect up to 4
JBODs.
Figure 3-8: Connecting Single-controller JBODs with S12F-G1433

3.4.1.3 Enclosure ID Settings

There is a rotary ID switch on every expansion enclosure that is
manually configured using a flat blade screwdriver. The configurable
IDs start from 1 to 6. Usually the numbering starts from the one
closest to the managing RAID enclosure.
The redundant-controller RAID connects to a maximum of 3 JBODs.
The single-controller RAID connects to a maximum of 4 JBODs.
Therefore, IDs 1 to 4 will be sufficient.
Chapter 3: Subsystem Connection
3-13