A.5

RAID Management

Specifications
Configuration
Performance
Monitoring
Remote Control
and Monitoring
Event
Broadcast/Alert
Event Notification
Hardware
Connection
Configuration on
Disk
Failure Indicator
A.6

Fault Tolerance Management

Specifications
Drive S.M.A.R.T Support
Battery Back-up Option
Sensors and module presence
detection through an I
Automatic Drive Failure Detection
Appendix A: Specifications
Operating: -10 to +70ºC
Storage: -30 to +70ºC
S12F-G1433
Operating: -10 to +60ºC
Storage: -20 to +70ºC
Text-based firmware-embedded utility
over RS-232C through the included serial
cable; Y-cable for the dual-controller
model.
Telnet via an established network
connection
LCD keypad panel
The SANWatch management suite using
in-band or Ethernet connection
Yes; http and web(SSL) access to an
embedded RAIDWatch manager
Yes
Yes, via SANWatch management suite
Yes, via SANWatch management suite
In-band over Fibre, out-of-band via Ethernet
or RS-232C
Configuration data stored on disks so that
logical drive configurations exist after
controller replacement; basic settings, e.g.,
channel mode settings, are stored on
NVRAM.
Faults are indicated via audible alarm, module
LED indicators, LCD panel, SANWatch
management suite, or terminal emulation.
Yes, with user-configurable
detect-only, clone and
replace, and perpetual clone
functions.
Yes, life expectancy and
charge level aware
Yes
2
C serial bus
Yes