Configuring The Rmon Ethernet Statistics Function; Configuring The Rmon History Statistics Function - H3C S5810 Series Operation Manual

Ethernet switches
Hide thumbs Also See for S5810 Series:
Table of Contents

Advertisement

Configuring the RMON Ethernet Statistics Function

Follow these steps to configure the RMON Ethernet statistics function:
To do...
Enter system view
Enter Ethernet interface view
Create an entry in the RMON
statistics table
Only one statistics entry can be created on one interface.
You can create up to 100 statistics entries for the device.

Configuring the RMON History Statistics Function

Follow these steps to configure the RMON history statistics function:
To do...
Enter system view
Enter Ethernet interface view
Create an entry in the RMON
history control table
The entry-number must be globally unique and cannot be used on another interface; otherwise, the
operation fails.
You can configure multiple history entries on one interface, but the values of the entry-number
arguments must be different, and the values of the sampling-interval arguments must be different
too; otherwise, the operation fails.
You can create up to 100 history entries for the device.
When you create an entry in the history table, if the specified buckets number argument exceeds
the history table size supported by the device, the entry will be created. However, the validated
value of the buckets number argument corresponding to the entry is the history table size
supported by the device.
Use the command...
system-view
interface interface-type interface-number
rmon statistics entry-number [ owner
text ]
Use the command...
system-view
interface interface-type interface-number
rmon history entry-number buckets
number interval sampling-interval [ owner
text ]
1-4
Remarks
Required
Remarks
Required