[Sysname-mtlk-group1] port gigabitethernet 1/0/2 downlink
Displaying and Maintaining Monitor Link
To do...
Display monitor link group
information
Monitor Link Configuration Example
Network requirements
As shown in
Figure
Device C is dually uplinked to Device A through a smart link group.
It is required that when GigabitEthernet1/0/1 or GigabitEthernet1/0/2 of Device A fails, Device C
can sense the link failure and perform link switchover in the smart link group.
For detailed information about smart link, refer to Smart Link Configuration in the Access Volume.
Figure 1-1 Network diagram for smart link in combination with monitor link configuration
GE1/0/1
GE1/0/1
GE1/0/2
Device B
GE1/0/1
Configuration procedure
1)
Configuration on Device C
# Disable STP on GigabitEthernet 1/0/1 and GigabitEthernet 1/0/2.
<DeviceC> system-view
[DeviceC] interface gigabitethernet 1/0/1
[DeviceC-GigabitEthernet1/0/1] undo stp enable
[DeviceC-GigabitEthernet1/0/1] quit
[DeviceC] interface gigabitethernet 1/0/2
[DeviceC-GigabitEthernet1/0/2] undo stp enable
Use the command...
display monitor-link group
{ group-id | all }
1-1:
Device A
GE1/0/2
GE1/0/1
GE1/0/2
Device D
GE1/0/2
Device C
1-3
Remarks
Available in any view