For tower models, place the server on a flat, level surface with the access panel facing up.
o
For rack models, extend the server from the rack (on page 33).
o
Open the access panel latch, slide the access panel to the rear of the chassis, and then remove the
5.
access panel.
If the access panel latch is locked, use a T-15 Torx screwdriver to unlock the latch.
Install the access panel
Place the access panel on top of the server with the hood latch open. Allow the panel to extend past the
1.
rear of the server approximately 1.25 cm (0.5 inch).
Push down on the hood latch. The access panel slides to a closed position.
2.
Use a T-15 Torx screwdriver to tighten the security screw on the hood latch.
3.
If the server is in a tower configuration, return the server to an upright position.
4.
If the server is in a rack configuration, slide the server into the rack.
5.