Remove A Fan - HP ProLiant ML350 Gen9 User Manual

Hide thumbs Also See for ProLiant ML350 Gen9:
Table of Contents

Advertisement

To install the component:
Install the air baffle.
1.
Install the access panel (on page 32).
2.
Do one of the following:
3.
If the server is in a tower configuration, return the server to an upright position.
o
If the server is in a rack configuration, slide the server into the rack.
o
Connect each power cord to the server.
4.
Connect each power cord to the power source.
5.
Power up the server (on page 29).
6.
Do one of the following:
7.
For tower models, install the tower bezel (on page 31).
o
For rack models, install the security bezel
o

Remove a fan

CAUTION:
all bays are populated with either a component or a blank.
To remove the component:
Do one of the following:
1.
For tower models, open and remove the tower bezel
o
For rack models, if installed, remove the security bezel
o
page 30).
Power down the server (on page 29).
2.
Remove all power:
3.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
To prevent improper cooling and thermal damage, do not operate the server unless
("Security bezel
option" on page 48)
("Remove the tower
("Remove the security bezel
bezel" on page 30).
(optional)" on
Operations 35

Hide quick links:

Advertisement

Table of Contents
loading