KTD-N0819-K
Environmental
Operating:
Conditions
0°C – 60°C operating temperature (forced cooling). It is the customer's
responsibility to provide sufficient airflow around each of the components to keep
them within allowed temperature range.
10% - 90% relative humidity (non-condensing)
Storage:
-20°C – 70°C; lower limit of storage temperature is defined by specification
restriction of on-board CR2032 battery. Board with battery has been verified for
storage temperature down to -40°C by Kontron.
5% - 95% relative humidity (non-condensing)
Electro Static Discharge (ESD) / Radiated Emissions (EMI):
All Peripheral interfaces intended for connection to external equipment are ESD/
EMI protected.
EN 61000-4-2:2000 ESD Immunity
EN55022:1998 class B Generic Emission Standard.
Safety:
IEC 60950-1: 2005, 2
UL 60950-1
CSA C22.2 No. 60950-1
Product Category: Information Technology Equipment Including Electrical
Business Equipment
Product Category CCN: NWGQ2, NWGQ8
File number: E194252
Theoretical MTBF:
268.956 / 131.729 hours @ 40ºC / 60ºC for the KTQM67/mITX
253.955 / 122.738 hours @ 40ºC / 60ºC for the KTQM67/Flex
236.956 / 113.462 hours @ 40ºC / 60ºC for the KTQM67/ATXP
Restriction of Hazardous Substances (RoHS):
All boards in the KTQM67 family are RoHS compliant.
Capacitor utilization:
No Tantalum capacitors on board
Only Japanese brand Solid capacitors rated for 100 ºC used on board