Field Settings
4.3

Outdoor Unit

4.3.1 Jumper Settings
Jumper
J3
J5
Location of the jumpers
Caution
Replace the PCB if you accidentally cut a wrong jumper.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of
them.
239
Function
ECONO operation
prohibition setting
Improvement of defrost
performance
1) Remove the
2 screws.
Electrical
box cover
Insulation
sheet
Fan motor lead wire
Hook
3) Remove the
electrical box cover
from the hook.
When connected
(factory set)
ECONO operation is
available.
Standard control
PCB
Trial Operation and Field Settings
SiBE121123_A
When cut
ECONO operation is disabled.
Reinforced control
(Ex: The frequency increases,
the duration time of defrost
lengthens.)
Top panel
2) Remove the
screw.
4) Remove the
insulation
sheet.
Notch
Electrical box
PCB
5) Cut the jumper.
(You can cut the jumper
with the PCB mounted.)
(R14361)