Troubleshooting For Ra Indoor Unit; Indoor Unit Pcb Abnormality - Daikin 2MXS40H2V1B Service Manual

Inverter multi for 2 rooms h-series / g-series
Hide thumbs Also See for 2MXS40H2V1B:
Table of Contents

Advertisement

Troubleshooting for RA Indoor Unit

5. Troubleshooting for RA Indoor Unit

5.1

Indoor Unit PCB Abnormality

A1
Error Code
Method of Error
The system checks if the circuit works properly within the microcomputer of the indoor unit.
Detection
Error Decision
The system cannot set the internal settings.
Conditions
Supposed
Causes
157
Wrong models interconnected
Defective indoor unit PCB
Disconnection of connector
Reduction of power supply voltage
SiBE121123_A
Service Diagnosis

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents