Inserting Cap (Sealing Plug) - PGO G-MAX 50 Service Manual

Hide thumbs Also See for G-MAX 50:
Table of Contents

Advertisement

Insert the nozzles of the electrolyte container into the
battery's electrolyte filler holes, holding the container
securely.
! CAUTION
Take precaution not to allow any of the fluid to spill.
Insert the nozzles squarely to the battery.
Check that air bubbles are coming up from each
electrolyte container and leave in this position for more
than 20 minutes.
NOTE:
If no air bubbles are coming up from the filler port, tap the
Bottom of the container two or three times.
Never remove the container from the battery.
! CAUTION
Make sure to fill all the amount of electrolyte into
The battery.
it is important to check all the cells are filled with electro-
lyte completely because insufficient filling of electrolyte in
even one cell will result in deteriorated performance and
shortened life.

INSERTING CAP (SEALING PLUG)

! CAUTION
Fit the cap securely.
To install the cap, temporarily fit the cap to all the cells
Lightly, thereafter press the cap little by little into each filler
Hole evenly and horizontally.
Inserting the cap at once in one cell and then in the next
Cell will cause the cap to deform resulting in poor sealing.
! CAUTION
Wipe completely if the filler hole is wet with electrolyte.
Do not remove the caps once it has been installed to the
battery.