Fuse Replacement - Martin Tripix 300 User Manual

Table of Contents

Advertisement

5.
Without disturbing the seal, reinstall the front cover, cross-
tightening screws gradually in steps to a torque of
1.6 Nm ± 0.1 Nm.

Fuse replacement

Warning! Lock out power to the entire distribution system before
servicing or opening any cover. Replace fuses with ones of the
same type and rating only. Do not attempt to bypass a fuse.
Tripix Power IP66
The fuse in the Tripix Power IP66 must be replaced by Martin Service
or its authorized agents only.
Tripix Power
The fuse in the Tripix Power can be replaced by the user following the
warnings and instructions below.
The Tripix Power is protected by a 6.3 amp slow-blow primary fuse. If
the Tripix Power is completely dead, the primary fuse may have been
blown.
To replace the fuse:
1.
Disconnect the Tripix Power from power.
2.
See Figure 39. Open the fuseholder located next to the power
cable entry with a flathead screwdriver and remove the fuse.
Figure 38: Reinstalling the front cover
TM
Tripix
Series User Manual
47

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tripix washTripix 1200Tripix power ip66Tripix power

Table of Contents