Fuse replacement

DANGER! Lock out power to the entire distribution system before servicing or opening any
cover. Replace fuses with ones of the same type and rating only.
Primary fuse
Exterior 200 LED fixtures are protected by a 2.5 amp slow-blow primary fuse located on the power PCB. If a
fixture is completely dead, the primary fuse may have blown.
To replace the primary fuse:
1. Isolate the fixture from power and allow to cool for 20 minutes.
2. Open the rear cover.
3. Replace a defective fuse with one of the same type and rating only. Replacement primary fuses are
available from Martin suppliers (P/N 05020013).
4. Check that the seal is in perfect condition, then reinstall the rear cover, gradually cross-tightening the
eight M6 screws working diagonally. Tighten to a maximum torque of 5 - 6 Nm (3.7 - 4.4 ft.-lbs.).
5. Reapply power.

Fixture readouts in MUM

Various types of data can be displayed by connecting a PC as described in "Connecting a PC with MUM" on
page 16 and clicking on the Monitor button:
Light1 displays the light level currently measured by light sensor 1 on the back of the fixture.
Voltage displays the current voltage in 48 V and 5 V circuits on the main PCB (this data is for service
purposes).
Temp displays the current temperature on the LED circuit board that gives the highest reading, the current
main PCB temperature and the current ambient temperature.
Fan1 displays the current cooling fan speed in RPM (revolutions per minute).

Software installation

It may be necessary to upload new software (i.e. firmware) to the Exterior 200 LED if you believe that the
product has a software-related fault or if you want to update to a newer version. Software updates are
Service and maintenance