Martin Tripix 300 User Manual page 20

Table of Contents

Advertisement

Warning! One Tripix Power can safely drive a maximum of:
24 Tripix 300s or
6 Tripix 1200s or
6 Tripix Wash fixtures, or
any mixture of Tripix fixtures that does not exceed 7.2 meters
(23 ft. 7 in.). A Tripix Wash counts as a Tripix 1200.
One Tripix Power IP66 can safely drive a maximum of:
12 Tripix 300s or
3 Tripix 1200s or
3 Tripix Wash fixtures or
any mixture of Tripix 300 and Tripix 1200 fixtures that does not
exceed 3.6 meters (11 ft. 10 in.). A Tripix Wash counts as a
Tripix 1200.
Warning! The maximum length of the power link from a Tripix
Power or Tripix Power IP66 to the last Tripix fixture on the power
link must not exceed the length of the devices' integral cable tails
plus 30 m (98 ft.). In other words, you can extend the standard
power link by up to 30 m.
Tripix system components
The Tripix system consists of:
A Tripix Power or Tripix Power IP66 – a power supply that
provides fixtures with power at 48 volts DC.
A Power Inserter cable (see Figure 12), P/N: 91611339, a Y-
shaped (3-way) cable that is used to connect a Tripix Power
device and data from a DMX controller (or PC with USB-DMX
Interface) to a chain of Tripix fixtures.