3.1.7
Switch Input Programming
This programming sequence will set how the two switch inputs on the telephone entry system control
board will operate. Switch input 1 is labeled PSW (postal switch) and is found on terminal 4 of the
main terminal strip. Switch input 2 is a two terminal auxiliary input located on the upper left hand
corner of the control board. These switch inputs can be programmed to activate their respective
relays (switch 1 - relay 1, switch 2 - relay 2). They can also be programmed so that switch 1 dials out
the phone number programmed in directory code 0, 00, 000, or 0000, and switch 2 dials out the
phone number programmed in directory code 1, 01, 001, or 0001. Each switch is programmed
independently.
Factory setting is: Switch input 1 = 0 (relay 1 activates), Switch input 2 = 0 (relay 2 activates).
1.
Press *23 and enter the four-digit MASTER CODE _ _ _ _ (beep).
2.
Press 1* (beep) to set switch 1, or press 2* (beep) to set switch 2.
3.
Press 0* (beep) to set the switch input to activate the relay, or press 1* (beep) to set
the switch input to dial-out a preprogrammed phone number.
4.
Press 0# TOGETHER to end this programming step (beeeeeep).
3.1.8

Touch-tone / Rotary-dial

This programming sequence will set the telephone entry system to dial out in either a touch-tone or
rotary format. Generally, this will be set for touch-tone.
Factory setting = 0 (touch-tone).
1.
Press *07 and enter the four digit MASTER CODE _ _ _ _ (beep).
2.
Enter 0* (beep) for touch-tone or enter 1* (beep) for rotary.
3.
Press 0# TOGETHER to end this programming step (beeeeeep).
3.1.9

Number of Rings to Answer

This programming sequence sets the number of rings to allow before the telephone entry system
answers a call placed to it. This programming sequence does not affect the number of times that a
resident's telephone will ring when a call is placed from the entry system to the resident.
Factory setting = 02 (two rings).
1.
Press *18 and enter the four-digit MASTER CODE _ _ _ _ (beep).
2.
Enter the number of rings _ _ then press * (beep).
3.
Press 0# TOGETHER to end this programming step (beeeeeep).

3.1.10 PBX Line Access Code Programming

If the telephone entry system is connected to a PBX telephone system rather than a dedicated C.O.
line, you may need to set the unit to dial a line access code prior to dialing the resident phone
number. Typically, the line access code is "9", but check with the PBX system administrator to be
sure.
1.
Press *21 and enter the four-digit MASTER CODE _ _ _ _ (beep).
2.
Enter the line access code number _ then press * (beep).
3.
Press 0# TOGETHER to end this programming step (beeeeeep).
NOTE: To change a line access number, enter the correct number in step 2. To
delete a line access number, enter # in step 2.