SYMPTON
Cannot get into
programming mode.
System emits a long
tone and cancels
programming.
Keypad is dead.
Buzz or noise on the
phone line.
Ringing or howling
from the speaker.
After dial out, dial tone
is heard on the
speaker.
Door strike locks on.
Door strike or gate
operator holds open.
Entry system will not
answer when called.
Rotary dial 9 will not
activate relay.
Touch-tone 9 will not
activate relay.
Relay activates but
gate operator will not
open.
Postal switch will not
activate relay.
Switch 2 input will not
activate relay.
Page 48
POSSIBLE SOLUTION(S)
Wrong master code entered. Start over.
Waiting too long between pushing buttons. Enter information quicker.
Keypad is not plugged into board correctly. Cable points down.
Memory chips are installed upside down.
Waiting too long between pushing buttons.
Forgetting to press * first when programming.
No power. Check for 16 VAC input power.
Check that the keypad is properly connected to the circuit board. The cable on
the plug points down when connected to the circuit board.
Disconnect the phone line from the system and check it with a handset. If line
is noisy, problem is with the phone line and not the entry system.
Check for any shorts to ground behind the circuit board.
Check for pinched wires near the door hinge.
Check for 16-volt power shorted to ground.
Check for phone line shorted to ground.
Check that phone wires are twisted.
Check that the proper type of phone wire was used for an outdoor and / or
underground application.
Check that all wires, speaker, keypad, etc. are isolated from ground.
Check that the cabinet is properly grounded.
(terminal 3) is not used as a low voltage common.
Check for excessive voltage drop on 16 VAC power.
Feedback improperly adjusted (4.2).
Volume is set too high (4.1).
Phone line is a rotary-dial line. Have the phone company change it to a touch-
tone line.
Excessive voltage-drop on 16 VAC line.
Using a transformer with too low VA rating.
Relay strike time programmed too long (3.1.3).
Auto relay time zone enabled. Turn auto relay feature off or reprogram the
time zone (5.2.5).
System was given a hold open command. Call the system and press the tone
deactivate number (5.2.2).
Ring pin is not installed (4.6).
Number of rings to answer is set to high. Reprogram (3.1.8).
Bad phone line or insufficient ring voltage.
Adjust click sensitivity (4.3).
Re-program tone-open number to 9 (3.1.5).
If resident phone emits a short pulse rather than a long tone, press 9 twice in
rapid succession 99.
Try another phone that is known to work.
Lower speaker volume (4.1) and re-adjust feedback (4.2).
Re-program relay strike time for a longer period (3.1.3).
Check wiring to gate operator.
Check gate operator.
Be sure that the wire-tie has been clipped off the postal switch.
Be sure that the relay has been programmed for postal switch input (3.1.6).
Reprogram switch input 2 to activate relay (3.1.6).
Be sure that case ground