5. Press any of the numeric buttons to quit the sequence
and return to spot monitoring.
Notes:
• The Auto Skip function can be programmed in the
menu setup to be applied to the sequence to skip any
steps where no video signal is present.
• You can individually run a sequence on the spot moni-
tor and on the multiscreen monitor. Select a monitor
with the [SPOT/MULTI] button, then press the SEQ but-
ton to start or pause a sequence on the respective
monitor.
G Viewing a Multiscreen Live
The multiscreen monitor can display multiscreen live
images. The available split patterns are: Quad A (input 1, 2,
3, 4), Quad B (input 5, 6, 7, 8), and 9-split (input 1-8).
1. Press the [MULTI SCREEN SELECT] button repeatedly.
The pattern changes every time the button is pressed
depending on the setup for MULTI SEQ SETUP.
When ALL is selected:
Pattern 4A → Pattern 4B → Pattern 9 → Pattern 4A
(4A)
MULTISCREEN
SELECT
1
2
3
4
9-split screen
1
4
7
When QUAD ONLY is selected:
Pattern 4A → Pattern 4B → Pattern 4A
(4A)
MULTISCREEN
SELECT
1
2
3
4

Alarm Control Function

The recorder performs alarm functions to warn the system
operators when an event has occurred.

I Alarm Input

There are four alarm inputs to the recorder that allow the
recorder to output warnings.
(4B)
MULTISCREEN
SELECT
5
6
7
8
MULTISCREEN
SELECT
2
3
5
6
8
(4B)
MULTISCREEN
SELECT
5
6
7
8
G Connected Alarm Sensors
A maximum of eight sensors can be connected to the termi-
nals on the rear panel. Sensors may be installed in such
places as parking lots or reception desks where cars and
visitors come and go.
G Built-in Motion Detector
The recorder detects motion for each of the eight video
inputs, based on certain changes in the video signal.
G Built-in Video Loss Detector
The recorder detects any disconnection of the video inputs.
The images of the disconnected channel will not be record-
ed.
G PC Alarm
The recorder receives an alarm from a PC.

I Alarm Output

The following outputs will be performed when TRIGGER
ACTION SETUP is set to REC&ALM in the REC SETUP
menu. Only recording will be performed when set to REC,
and no action will take place when set to OFF.
G Front Panel Indicators
When an alarm is received, the ALARM indicator blinks and
the LED in the corresponding [CAMERA SELECT] button
blinks. More LEDs will blink when more alarm inputs arise.
The LED will stop blinking when the preset time has
elapsed (Auto Reset), when the [RESET] button is pressed
on the front panel (Manual Reset), when the external reset
signal is received on the rear panel (External Reset), or
when the video signal lost on any channel is restored
(Video Loss).
The ALARM indicator will change from blinking to a steady
light when Auto Reset or External Reset is implemented.
This steady light notifies the system operator that there
have been alarm activations that have not yet been manual-
ly reset.
ALARM
SUSPEND
RESET
CAMERA SELECT
1
2
5
6
3
4
7
8
47