I How To Use The Terminals Of The Alarm/Control Connector - Panasonic WJ-HD309 Operating Instructions Manual

Digital disk recorders
Hide thumbs Also See for WJ-HD309:
Table of Contents

Advertisement

I How to Use the Terminals of the ALARM/CONTROL Connector

These terminals are used for emergency recording, auto time adjustment (Auto Adjust Time), taking measures against power
outages (Shutdown Time), and when installing a buzzer, a lamp, or similar alarm device. They are also used to synchronize
with the sequential display changeover.
The terminal pin array and connections are shown below.
The connector used should be compatible with the pin con-
figuration.
Pin array
Pin No.
q
Ch 8 alarm output
w
Ch 9 alarm output
e
Ch 10 alarm output
r
Ch 11 alarm output
t
Ch 12 alarm output
y
Ch 13 alarm output
u
Ch 14 alarm output
i
Ch 15 alarm output
o
Ch 16 alarm output
!0
NC
!1
Alarm display reset input
Emergency recording
!2
input
!3 , !4
Earth (Grounding)
Alarm output for available
!5
disk space of device con-
nected to copy port
!6
HDD error output
!7
Camera error output
!8
Error output
End of outage process-
!9
ing
@0
Time adjustment I/O
Sequence changeover
@1
I/O
@2
Alarm suspension input
@3
Outage detection I/O
External recording mode
@4
changeover
@5
+5 V output
80
Pin No.
Alarm signal output at an event occurrence
Canceling the alarm display
Starting emergency recording disk space a sig-
nal input
Generation of signal output for disk space alarm-
ing of DVD-RAM, DVD-R, CD-R
Signal output upon detection of HDD error
Signal output upon detection of camera error
Signal output upon detection of unit error
Signal output upon completion of outage pro-
cessing
Time of this unit is adjusted to the preset time
according to the signal input. This signal output is
then generated for the setting time of this unit.
Time of all other units is adjusted to the setting
time of this unit.
Sequence changeover is effected according to
the signal input. Signal output is generated at the
time of sequence changeover.
The state of alarm suspension is assumed
according to the signal input.
Start of outage processing according to the sig-
nal input.
Changeover to the external recording mode
+5 V output
!3
ALARM/CONTOROL
@5
Operation
q
!4
Remarks
Open collector output
24 V max., 100 mA
Non-voltage make contact input
–100 mA, 5 V pull-up
Open collector output
24 V max., 100 mA
High (+12 V)
30 kΩ 5 V pull-up,
–100 mA/make contact
Non-voltage make contact input
–100 mA/5 V pull-up
200 mA max.