Motion Sensitivity; Motionless Timeout - Datalogic PowerScan PD9530 Product Reference Manual

9500 family industrial corded handheld area imager bar code reader
Hide thumbs Also See for PowerScan PD9530:
Table of Contents

Advertisement

Enter/Exit Programming Mode

Motion Sensitivity

Defines discrete set of levels for scanner motion sensitivity when in hand-
held use.
$CMOSY01(CR)
Motion Sensitivity = Medium

Motionless Timeout

Specifies the waiting time in 100 millisecond ticks to assume that the reader
is in a motionless condition. The selectable range is 500 msec to 25.5 Sec-
onds. When no motion event is detected for a period of time longer than this
timeout, the software assumes the reader is in a motionless condition. This
option relates to such features as Aimer On and Stand Mode Object Sense
scanning with respect to motion. See
References.
$CMOTO
Select Motionless Timeout Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
DEFAULT
206
$CMOSY00(CR)
$CMOSY02(CR)
"Motionless Timeout" on page 303
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar
code at left followed by three digits from the Alpha-
numeric characters in
resenting your desired character(s). End by scanning
the ENTER/EXIT bar code again.
020 = Motionless Timeout = 2 seconds
Motion Sensitivity = Low
DEFAULT
Motion Sensitivity = High
Appendix D, Keypad
~