Code 39 Start/Stop Character Transmission

Enable this option to enable/disable transmission of Code 39 start and stop
characters
DEFAULT
$CC3SS01(CR)
Code 39 Start/Stop Character Transmission = Transmit

Code 39 Full ASCII

Enables/disables the translation of Code 39 characters to Code 39 full-
ASCII characters.
DEFAULT
$CC3FA01(CR)
Code 39 Full ASCII = Enable
Product Reference Guide
.
Enter/Exit Programming Mode
$CC3SS00(CR)
Code 39 Start/Stop Character Transmission =
Don't Transmit
$CC3FA00(CR)
Code 39 Full ASCII = Disable