Isbt 128 Dynamic Concatenation Timeout; Isbt 128 Advanced Concatenation Options - Datalogic PowerScan PD9530 Product Reference Manual

9500 family industrial corded handheld area imager bar code reader
Hide thumbs Also See for PowerScan PD9530:
Table of Contents

Advertisement

Enter/Exit Programming Mode

ISBT 128 Dynamic Concatenation Timeout

Specifies the timeout used by the ISBT 128 Dynamic Concatenation Mode.
$CI8DT0A(CR)
ISBT 128 Dynamic Concatenation Timeout = 100 msec
DEFAULT
$CI8DT32(CR)
ISBT 128 Dynamic Concatenation Timeout = 500 msec
$CI8DT64(CR)
ISBT 128 Dynamic Concatenation Timeout = 1 second

ISBT 128 Advanced Concatenation Options

To set up pairs of label types for concatenation, use the Datalogic Aladdin configura-
tion application or contact Datalogic Technical Support, as described on
122
$CI8DT05(CR)
ISBT 128 Dynamic Concatenation Timeout = 50 msec
$CI8DT14(CR)
ISBT 128 Dynamic Concatenation Timeout = 200 msec
$CI8DT4B(CR)
ISBT 128 Dynamic Concatenation Timeout = 750 msec
PowerScan™ PD9530/PBT9500/PM9500
page 2
.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerscan pbt9500Powerscan pm9500Pd9530Pbt9500Pm9500Powerscan 9500 series

Table of Contents