Checks To Perform After Start-Up; Winter Storage; Maintenance; Maintenance Instructions - Zodiac PF Premium 6M Instructions For Installation And Use Manual

Swimming pool heat pump
Hide thumbs Also See for PF Premium 6M:
Table of Contents

Advertisement

 if the heat pump is on stand‐by: 
for 2 seconds, and 
, a 2‐minute delay will start,   
 set the required water temperature:  
 to increase temperature,  
- press 
 to decrease temperature, 
- press 
 
When the pool reaches the required temperature, the heat pump will automatically stop. 
 
 set  the  water  flow‐rate  using  the  menu  ,  when  the  indicator 
flow‐rate status:  
 
Status 
water flow‐rate ok 
Display 
 
 set the flow‐rate using valve 5 (or 3 if no valve 5 is fitted), and, to quit the menu, press 
 
During this adjustment phase, wait for a few minutes after each change in valve position to allow the 
 
device to balance. 
 
3.3 Checks to perform after start‐up 
 
The heat pump must stop when:  
 the set‐point temperature is lowered using the digital control panel,  
 filtering is stopped or valve 2 or 3 is closed 3,  
 the digital control panel is turned off by pressing 
 
3.4 Winter storage 
 
Winter storage is essential due to the risk of the condenser freezing and breaking. This situation is not 
covered by the warranty. 
 
To avoid damaging the device with condensation, do not cover it with an air‐tight cover. 
 
 switch the digital control panel to "stand‐by" mode by pressing 
 open valve 1, 
 close valves 2 and 3, and open valves 4 and 5 (if fitted),  
 ensure that no water is flowing through the heat pump,  
 drain  the  water  condenser  by  unscrewing  the  two  pool  water  inlet  and  outlet  connections  at  the  back  of  the 
heat pump,  
 in the case of full winter storage conditions for the pool: re‐connect the inlet and outlet connections to avoid 
foreign bodies entering into the condenser,  
 in the case of winter storage for the heat pump alone: do not reconnect the inlet and outlet connectors, instead 
place two plugs (supplied) on the condenser water inlet and outlet. 
 cover the heat pump with a micro‐breathing overwintering cover (optional accessory, see §4.3).  
 
4. Maintenance 
 
4.1 Maintenance instructions
 
It  is  recommended  that  the  device  be  general  serviced  on  a  yearly  basis  to  ensure  proper  operation, 
maintain performance levels and prevent some potential failures. 
 
This is the responsibility of the user and must be performed by a qualified technician. 
Do not use a high‐pressure water hose. 
 
H03620‐00.B5.EN – 2011/11
 for 3 seconds, and the water and set‐point temperatures will be displayed: 
no water flow 
 
 
 
 for 3 seconds, 
, press on 
  is  steady:  press 
water flow‐rate too weak 
,  
 for 3 seconds, and cut the power supply,  
 
 will appear 
  to  display  the  water 
water flow‐rate too strong 