if the heat pump is on stand‐by:
for 2 seconds, and
, a 2‐minute delay will start,
set the required water temperature:
to increase temperature,
- press
to decrease temperature,
- press
When the pool reaches the required temperature, the heat pump will automatically stop.
set the water flow‐rate using the menu , when the indicator
flow‐rate status:
Status
water flow‐rate ok
Display
set the flow‐rate using valve 5 (or 3 if no valve 5 is fitted), and, to quit the menu, press
During this adjustment phase, wait for a few minutes after each change in valve position to allow the
device to balance.
3.3 Checks to perform after start‐up
The heat pump must stop when:
the set‐point temperature is lowered using the digital control panel,
filtering is stopped or valve 2 or 3 is closed 3,
the digital control panel is turned off by pressing
3.4 Winter storage
Winter storage is essential due to the risk of the condenser freezing and breaking. This situation is not
covered by the warranty.
To avoid damaging the device with condensation, do not cover it with an air‐tight cover.
switch the digital control panel to "stand‐by" mode by pressing
open valve 1,
close valves 2 and 3, and open valves 4 and 5 (if fitted),
ensure that no water is flowing through the heat pump,
drain the water condenser by unscrewing the two pool water inlet and outlet connections at the back of the
heat pump,
in the case of full winter storage conditions for the pool: re‐connect the inlet and outlet connections to avoid
foreign bodies entering into the condenser,
in the case of winter storage for the heat pump alone: do not reconnect the inlet and outlet connectors, instead
place two plugs (supplied) on the condenser water inlet and outlet.
cover the heat pump with a micro‐breathing overwintering cover (optional accessory, see §4.3).
4. Maintenance
4.1 Maintenance instructions
It is recommended that the device be general serviced on a yearly basis to ensure proper operation,
maintain performance levels and prevent some potential failures.
This is the responsibility of the user and must be performed by a qualified technician.
Do not use a high‐pressure water hose.
H03620‐00.B5.EN – 2011/11
for 3 seconds, and the water and set‐point temperatures will be displayed:
no water flow
for 3 seconds,
, press on
is steady: press
water flow‐rate too weak
,
for 3 seconds, and cut the power supply,
will appear
to display the water
water flow‐rate too strong
.
8