Zodiac PW 5M Instructions For Installation And Use Manual
Zodiac PW 5M Instructions For Installation And Use Manual

Zodiac PW 5M Instructions For Installation And Use Manual

For swimming pool

Advertisement

PW
 
5M-7M-9M-11M
Instructions for installation and use
SA
English
Ver. : 11/2011

Advertisement

Table of Contents
loading

Summary of Contents for Zodiac PW 5M

  • Page 1   5M-7M-9M-11M Instructions for installation and use English Ver. : 11/2011...
  • Page 2: Table Of Contents

     Summary    Installation .................. 2     1.1 General ...................... 2   1.2 Operating conditions .................. 3   1.3 Installation  ...................... 3   Operation .................. 6     2.1 The Control Panel .................... 6   2.2 Checks to be performed before operating the appliance ......... 7   2.3 Starting the appliance  .................. 7   2.4 Checks to perform after operating the appliance .......... 7   2.5 Winterizing ...................... 8   Maintenance ................... 8     3.1 Maintenance instructions  .................. 8   3.2 Recycling the product .................. 9   3.3 Additional recommendations  ................ 9  ...
  • Page 3: Installation

    Installation    1.1 General    1.1.1 Caution     Exclusive  use:  heating  swimming  pool  water  (not  be  used  for  any  other  application),   the  product  must  be  installed  by  a  qualified  technician  according  to  the  manufacturer’s  instructions  and  in  compliance  with  local  regulations.  The  installer ...
  • Page 4: Operating Conditions

    In  the  case  of  damage  caused  during  shipping  the  recipient  must  mention  any  reservations  in  writing  on  the  carrier's  delivery  note  (confirmation  to  be  sent  to  the  carrier within 48 hours by registered mail and Acknowledgement of Receipt).  If the appliance has been turned on its side, mention your reservations in writing to  the carrier.     1.1.3 Contents         X1    1.2 Operating conditions  Operating range:   ...
  • Page 5 It is possible to fix the appliance to the ground using the holes in the base of the  appliance or using fixing rails (not supplied). It is also possible to fix the appliance  with brackets (not supplied).  A drilling explanation diagram is available on the rear of the packaging box.      1.3.3 Hydraulic connections      With by‐pass    (recommended)    Without by‐pass         * Minimum distance    filter    water treatment    by‐pass          Respect  the  direction  of  the  hydraulic  connection  (see  §  "Dimensions"  in  the  appendix). ...
  • Page 6 Installing a by‐pass is mandatory if the water flow is higher than 8m³/h, use valve VB to  adjust the water flow and leave valves VE and VS open.    PW  11M  Test pressure  Operating pressure  Head Loss  2.45 4.95 5  Minimum water flow‐rate  m³/h Average water flow‐rate  m³/h 5  Maximum water flow‐rate*  m³/h * this flow‐rate must not be exceeded    1.3.4 Electrical connections     the  unit  is  designed  for  connection  to  a  general  power  supply  with  full  earth  and  neutral or neutral earth systems,   electrical  protection:  by  circuit‐breaker  (curve  D)  or  fuse  (Am),  and  with  a  30  mA  differential trip switch at the head of the supply line (circuit‐breaker or switch). ...
  • Page 7: Operation

     supply cable section: for cables of a maximum length of 20 metres (calculation base:  5A/mm²), must be checked and adapted depending on installation conditions      Maximum current  Cable section  Electrical protection  consumption  PFP  Voltage  A  mm²    A  11M  230V‐50Hz  15.5 3 x 2.5  3G2.5 16    phase (L) + neutral (N) + Earth (PE)       electrical conduits must be secured,   use the stuffing box to bring the supply cable into the appliance.      Operation  2.1 The Control Panel      Symbol  Designation  Not flashing  Flashing Off  Water flow is ...
  • Page 8: Checks To Be Performed Before Operating The Appliance

      Symbol  Designation Not flashing  Flashing Off    setting values buttons     2.2 Checks to be performed before operating the appliance   the hydraulic connections must be tight,   the unit must be stable (as well as level and upright),   the electrical supply cable must not be exposed to sharp or hot elements which could  damage it or crush it.    2.3 Starting the appliance   open the water supply and adjust the valves, if any (see §1.3.3),   connect the heat pump to the power supply :   then  ,   to  turn  on  the  appliance:  press  for  2  seconds  on   :    then   by default the screen will display the requested  temperature,  ...
  • Page 9: Winterizing

    2.5 Winterizing    Winterizing is essential due to the risk of the condenser freezing. This situation is  not covered by the warranty.      switch off the heat pump by pressing the     button for 2 seconds, then disconnect  the power cable,    ensure that no water is flowing through the heat pump,    drain the water condenser (risk of freezing) by removing the two pool water inlet and  outlet connections at the back of the heat pump,    in the case of a full winterizing of the pool: connect the inlet and outlet connections  "lightly" without tightening (one turn) in order to avoid foreign bodies entering into  the condenser,    in the case of winterizing the heat pump alone: do not reconnect the inlet and outlet  connectors,  instead  place  two  stops  (supplied)  on  the  condenser  water  inlet  and  outlet.    To avoid damaging the appliance with condensation, do not cover it with an air‐ tight cover.     Maintenance   ...
  • Page 10: Recycling The Product

      3.2 Recycling the product  This  symbol  means  that  the  equipment  must  not  throw  it  into  your  household  waste.  It  will  be  collected  selectively  so  that  it  can  be  reused,  recycled  or  recovered.  Any  substances  it  may  contain  which  are  potentially  dangerous to the environment will be eliminated or neutralised.  Enquire with your retailer for the conditions that apply to the recycling of your product.   ...
  • Page 11: Error Codes

     the high pressure circuit pipes are made of copper and have a diameter equal to or  greater than 1’’5/8. A certificate as indicated in §2.1 in compliance with standard NF  EN  10204  will  be  requested  from  the  supplier  and  filed  in  the  installation  technical  documentation.   the  technical  data  relative  to  the  safety  requirements  of  the  various  applicable  directives  must  be  indicated  on  the  name  plate.  This  data  must  be  recorded  in  the  unit ...
  • Page 12: Faq

    FAQ     Is it possible to improve the temperature performance?  A heat pump is designed to extract heat from the surrounding air and transfer it to  the pool water. The higher the air temperature, the more heat the heat pump will be  able to transfer to the pool water.   Setting the setpoint to maximum will not heat the water any faster.    In order to improve the efficiency of your heat pump it is recommended that you:  - protect the pool with a cover (floating cover, roller cover …), so as to avoid heat  loss,  choose  periods  when  the  outside  temperature  is  mild  (>  on  average  10°  C)  in  order  to  facilitate  the  temperature  increase  (this  may  take  several  days.  The  actual time will vary according to weather conditions and the power of the heat  pump),  ...
  • Page 13: Technical Information

     The heat pump is giving off water: is this normal?  Your  appliance  will  give  off  water  in  the  form  of  condensation.  This  water  is  the  humidity  contained  in  the  air  which  condenses  on  contact  with  certain  cold  components inside the heat pump.   Caution: your appliance can drain several litres of water per day.     Where  should  my  water  treatment  system  be  positioned  with  respect  to  the  heating system? ...
  • Page 14 In  particular,  the  spare  parts  warranty  will  only  be  honoured  after  analysis  and  inspection  of  the  returned  spare  parts  by  our  company  followed  by  the  decision  to  replace said parts.  In all cases the seller's legal warranty will continue to apply.  In order to benefit from the warranty, the Client and the End User agree to respect the  following parameters concerning the water balance of the swimming pool: pH: 6.8 < pH  < 7.6; free chlorine: < 3,0 mg/L; total bromine: < 5.0 mg/L; stabilising agent (if used): <  75 mg/L; total dissolved metals (iron, manganese, copper, zinc…) : < 0.1 mg/L   Note: using water drawn from a well is forbidden.    General limitations  The present warranty does not apply to visible defects that the Client failed to report  upon accepting delivery of the Products.  Also excluded from the warranty are: defects or deterioration due to the unsuitability  of  the  Product  with  respect  to  the  end  User's  needs,  due  to  normal  wear,  to  negligence, ...
  • Page 15: Registration On Line

    The  heat  exchanger  of  the  heat  pumps  benefits  from  a  5‐year  warranty  against  corrosion.      For any warranty issues, please contact your local retailer. We recommend that you keep your purchase invoice safe, if you require assistance  for your product.      Registration on line    Register your product on our website:   - you will be the first to be informed of new Zodiac products and special offers,  - You can help us to constantly improve the quality of our products.    Australia – New Zealand www.zodiac.com.au South Africa www.zodiac.co.za Europe and rest of the world www.zodiac‐poolcare.com      Conformity certificate   ...
  • Page 16  Electric diagram       PW 5M‐7M‐9M  English Power supply 230V‐1N‐50Hz                       H03579‐03.A1.SA  Ver. 11/2011  1 ...
  • Page 17       PW 11M L‐N‐PE English Power supply 230V‐1N‐50Hz                         H03579‐03.A1.SA  Ver. 11/2011  2 ...
  • Page 18   AF  Digital display    Earth  C1  Compressor capacitor  C2  Fan capacitor  C3  Auxiliary pump capacitor CD  Flow rate controler  E1  High pressure switch  E2  Low pressure switch  ED1  Auxiliary pump  F1  Fuse  KM1  Compressor relay  KM2  Fan relay  KM3  Auxiliary pump relay  KM4  Complementary relay  M1  Compressor  M2  Fan  M3  Auxiliary pump (150W‐200W maximum) SD1  Water temperature sensor SD2  Air temperature sensor SD3  Defrost sensor  T1 ...
  • Page 19   PW  weight (Kg)  5M  45  7M  47  9M  11M                       English pool water inlet  pool water outlet  Evaporator    H03579‐03.A1.SA  Ver. 11/2011  4 ...
  • Page 20 Voor nadere inlichtingen kunt u zich wenden tot uw zwembadbouwer. Para cualquier información adicional, contactar con su detallista. Per qualsiasi informazione supplementare, mettetev in contatto con il vostro rivenditore. ZODIAC® is a registered trademark of Zodiac International, S.A.S.U., used under license.

Table of Contents