Operating Conditions; Technical Specifications; Installation; Access To The Technical Compartment - Zodiac PF Premium 6M Instructions For Installation And Use Manual

Swimming pool heat pump
Hide thumbs Also See for PF Premium 6M:
Table of Contents

Advertisement

1.3 Operating conditions 
 
Operating range:
 
 air temperature of between 5 °C and 38 °C for standard models, 
 air temperature of between ‐8 °C and 38 °C for TSR models, 
 water temperature of between 10 °C and 32 °C,  
 
Maximum temperature of 32°C to protect the pool liner.  
 
Models TSR can make de‐ice by forced ventilation or a reverse cycle. 
 
1.4 Technical specifications 
 
PFP 
Voltage 
6M 
230V‐50Hz 
8M 
230V‐50Hz 
11M 
230V‐50Hz 
11T 
400V‐50Hz 
13M 
230V‐50Hz 
11M TSR  230V‐50Hz 
11T TSR 
400V‐50Hz 
15M TSR  230V‐50Hz 
15T TSR 
400V‐50Hz 
 
* with ambient air at +15 °C, pool water at 26 °C, and relative humidity of 70% ( according to French standard NF‐
414) 
 protection class: IP 24 
 refrigerant gas: R410A  
 refrigerant charge: see product information plate 
 
2. Installation 
 
Do not pick up the device using the outer casing, use the base. 
 
 
2.1 Access to the technical compartment 
 
    
 
2.2 Selecting an installation site 
 
The  device  must  be  installed  outdoors  and  there  must  be  adequate  open  space  surrounding  it  (see 
 
§2.4). 
 
 the heat pump must be installed at a minimum distance from the end of the pool so as to avoid exposure to 
water splashes. The appropriate distance should be defined with reference to the national electrical standards 
that apply in the country of installation (in France: 3.5meters). 
 the heat pump must not be installed:  
- near a source of heat or inflammable gas,  
- near a road with the risk of water and mud splashes,  
- facing a strong wind,  
- with  the  vent  facing  toward  a  permanent  or  temporary  obstacle  (window,  wall,  hedge,  etc...),  it  must  be  at 
least 4 meters from such.  
H03620‐00.B5.EN – 2011/11
Power input*    
kW 
1.4 
1.7 
2.2 
2.2 
2.88 
2.2 
2.2 
3.6 
3.6 
             
 
Power output* 
kW 
6.8 
7.6 
10.4 
10.5 
13.9 
10.7 
10.5 
15.7 
15.7 
 class: I,  
 degree of pollution: 2,  
 overvoltage category: II 
            
 
Nominal current input* 
6.7 
7.9 
10.3 
4.25 
13 
10 
4.4 
16 
7.4 
 
COP*
4.7 
4.5 
4.7 
4.8 
4.8 
4.9 
4.8 
4.5 
4.5 

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pf premium 11m tsrPf premium 11t tsrPf premium 15t tsr