1.3 Operating conditions
Operating range:
air temperature of between 5 °C and 38 °C for standard models,
air temperature of between ‐8 °C and 38 °C for TSR models,
water temperature of between 10 °C and 32 °C,
Maximum temperature of 32°C to protect the pool liner.
Models TSR can make de‐ice by forced ventilation or a reverse cycle.
1.4 Technical specifications
PFP
Voltage
6M
230V‐50Hz
8M
230V‐50Hz
11M
230V‐50Hz
11T
400V‐50Hz
13M
230V‐50Hz
11M TSR 230V‐50Hz
11T TSR
400V‐50Hz
15M TSR 230V‐50Hz
15T TSR
400V‐50Hz
* with ambient air at +15 °C, pool water at 26 °C, and relative humidity of 70% ( according to French standard NF‐
414)
protection class: IP 24
refrigerant gas: R410A
refrigerant charge: see product information plate
2. Installation
Do not pick up the device using the outer casing, use the base.
2.1 Access to the technical compartment
2.2 Selecting an installation site
The device must be installed outdoors and there must be adequate open space surrounding it (see
§2.4).
the heat pump must be installed at a minimum distance from the end of the pool so as to avoid exposure to
water splashes. The appropriate distance should be defined with reference to the national electrical standards
that apply in the country of installation (in France: 3.5meters).
the heat pump must not be installed:
- near a source of heat or inflammable gas,
- near a road with the risk of water and mud splashes,
- facing a strong wind,
- with the vent facing toward a permanent or temporary obstacle (window, wall, hedge, etc...), it must be at
least 4 meters from such.
H03620‐00.B5.EN – 2011/11
Power input*
kW
1.4
1.7
2.2
2.2
2.88
2.2
2.2
3.6
3.6
Power output*
kW
6.8
7.6
10.4
10.5
13.9
10.7
10.5
15.7
15.7
class: I,
degree of pollution: 2,
overvoltage category: II
Nominal current input*
A
6.7
7.9
10.3
4.25
13
10
4.4
16
7.4
COP*
4.7
4.5
4.7
4.8
4.8
4.9
4.8
4.5
4.5
3