Elimination of condensation: 
Warning: your device can produce several liters of water per day. You are strongly recommended to guide 
the flow to drains. 
 connect  a  Ø18  interior  pipe  (not  supplied),  to  the  grooved  end  piece  mounted  on  the  base  of  the 
appliance,  
 
 outlet: to the back or on the side: 
 
2.5 Electrical connections  
 
2.5.1 Voltage and protection 
 
 the  electrical  supply  to  the  heat  pump  must  pass  via  a  protection  and  disconnection  device  (not  supplied) 
complying with the standards and regulations in force in the country, 
 additional protection may be required during installation to guarantee overvoltage category II,  
 the device is designed for connection to a general power grid with TT and TN.S grounding systems,  
 electrical  protection:  circuit‐breaker  (curve  D)  or  fuse  (Am)  (see  §  2.5.3  for  ratings),  and  with  a  30  mA 
differential trip switch (circuit‐breaker or switch) dedicated. 
 
 electrical conduits must be secured, 
 tolerance for voltage variation: ± 6% (during operation),  
 use  cable  suitable  for  outdoor  use,  type  RO2V  or  equivalent  in  countries  outside  of  the  European 
 
community, and with an outer diameter between 9 and 18 mm, 
 use the stuffing box to run the supply cable into the device. 
 
2.5.2 Connections 
 
 the electrical supply cable must not be exposed to elements that are sharp, hot or represent a crush hazard,  
 check that all cables are secure and all terminal connections are correct. 
 
Loose terminals may cause the supply terminal board to overheat, and will void the warranty. 
The device must be connected to an earth electrode. 
Risk of electric shock inside the device.  
 
The device must only be connected by a qualified and experienced technician. 
If the power cable is damaged, it must be replaced by a qualified technician. 
 
Single‐phase  
 
phase (L) + neutral (N) + Earth (PE) 
 
 
2.5.3 Cable cross‐sections 
 
•supply  cable  cross‐section:  cables  with  a  maximum  length  of  20  metres  (calculation  base:  5A/mm²),  must  be 
checked and adapted depending on installation conditions.
 
PFP 
Voltage 
6M 
230V‐50Hz 
8M 
230V‐50Hz 
11M 
230V‐50Hz 
11T 
400V‐50Hz 
13M 
230V‐50Hz 
15M 
230V‐50Hz 
15T 
400V‐50Hz 
H03620‐00.B5.EN – 2011/11
Maximum I input 
10 
14.5 
16.1 
22 
9.4 
 
 
Three‐phase 
phases (L1 + L2 + L3) + neutral (N) 
 
  
Cable cross‐section 
mm² 
 
3 x 2.5  
3G2.5 
3 x 2.5  
3G2.5 
3 x 2.5  
3G2.5 
5 x 2.5 
5G2.5 
3 x 4 
3G4 
3 x 6  
3G6 
5 x 2.5 
5G2.5 
 
+ Earth (PE) 
Electrical protection 
16 
16 
16 
10 
20 
25 
10 