Configuring Multiple Supplies For Series Operation; Figure 3.2 Series Operation Of Multiple Supplies - Xantrex XFR 7.5-140 Operating Manual

Xfr 1200 watt series programmable dc power supply
Hide thumbs Also See for XFR 7.5-140:
Table of Contents

Advertisement

Local Operation
Using Multiple Supplies
Configuring
Multiple
Supplies for
!
Series
Operation
!
Use series operation to obtain a single higher voltage output using two or more
supplies. Connect the negative (–) output terminal of one supply to the positive (+)
output terminal of the next supply. See Figure 3.2. The total voltage available is the
sum of the maximum voltages of each supply (add voltmeter readings, to a maximum
of 600 V). The maximum allowable current for a series string of power supplies is
the output current of a single supply in the string.

Figure 3.2 Series Operation of Multiple Supplies

66
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
CAUTION
Do not use remote sensing during series operation.
CAUTION
The maximum allowable sum of the output voltages is 600 Vdc.
(Local sense lines shown are default J10 connections.)