4. REPLACEMENT PROCEDURE
68
5. Pull out the control board assembly
from the main body. (8 screws)
NOTE
• When pulling out the control board
assembly, be sure to hold the 2
hinge screws provided on the upper
and lower sections and pull them
out to this side.
• The board may be damaged due to
static electricity. Be sure to take an
appropriate measure against static
electricity before conducting the
operations.
6. Open the tab of the memory slot of
the control board and remove the
memory.
NOTE
• When reinstalling the memory, take
note of the direction in which the
DIMM is inserted. And be sure to
tab
insert it securely until the tabs on
both sides of the slot are set fully
into the notches on the DIMM side.
• Reinstall the above parts following
the removal steps in reverse.
Service Manual
Field Service Ver. 7.0 Jan. 2009
Y104784-2