Olivetti FK-502 Service Manual page 101

Hide thumbs Also See for FK-502:
Table of Contents

Advertisement

7. SERVICE MODE
5. Select the item and change parameter setting by pressing the [ + ] key / [ - ] key.
6. Press the [END] key to return Service Mode screen.
Parameter
Protocol
V8 / V34 Protocol
V17 EP TONE
V29 EP TONE
V17 Selection Mode
"-"
ANSam Send Time
Int'l Comm.
Foreign Communica-
Function
tion Function
No. of DIS Waiting
Times at Foreign
Communication
V34 Speed
V17 Speed
V29 Speed
TIMER 1
T1
DCS-TCF DELAY
CED-DIS DELAY
PIX-PMC DELAY
94
Set Value
ON / OFF
ON / OFF
ON / OFF
ON / OFF
1.0 to 5.5 [sec]
(in steps of 0.5 ms)
ON / OFF
1, 2 [times]
33600 to 16800 [bps]
(in steps of 2400)
14400 to 7200 [bps]
(in steps of 2400)
9600 to 2400 [bps]
(in steps of 2400)
30 to 90 [sec]
(in steps of 5 sec)
50 to 150 [ms]
(in steps of 10 ms)
50 to 150 [ms]
(in steps of 10 ms)
50 to 150 [ms]
(in steps of 10 ms)
Service Manual
Field Service Ver. 7.0 Jan. 2009
15LAF3E025DA
Factory-shipped
Reference
default setting
ON
ON
Yes
OFF
Yes
OFF
Yes
4.0 [sec]
Yes
ON
Yes
1 [time]
28800 [bps]
7200 [bps]
4800 [bps]
35 [sec]
Yes
80 [ms]
Yes
80 [ms]
Yes
80 [ms]
Yes
Y104784-2

Advertisement

Table of Contents
loading

Table of Contents