Removing The Front System Fan Cage Assembly - Lenovo ThinkServer TD100 Hardware Maintenance Manual

Types 6398, 6399, 6419, 6429, 4203, 4204, 4205, and 4206
Hide thumbs Also See for ThinkServer TD100:
Table of Contents

Advertisement

Removing the front system fan cage assembly

Attention:
v Replace a failed fan within 48 hours.
v To ensure proper cooling and airflow, do not operate the server for more than 30
To remove the front system fan cage assembly, complete the following steps.
1. Read the safety information that begins on page vii and "Installation guidelines"
2. Turn off the server and all attached devices; then, disconnect all power cords
3. Unlock and remove the side cover (see "Removing the side cover" on page 78).
4. Rotate the power-supply cage assembly out of the chassis:
5. Press in on the fan cage assembly release buttons on both sides of the chassis
6. Pull the fan cage assembly up and out of the chassis.
7. If you are instructed to return the fan cage assembly, follow all packaging
108
ThinkServer TD100 and TD100x: Hardware Maintenance Manual
minutes with the side cover removed.
on page 73.
and external cables.
v Hot-swap models:
a. Remove the hot-swap power-supply. Press down on the orange release
lever and pull the power supply out of the bay, using the handle.
b. Lift up the power-supply cage handle and pull the power-supply cage
assembly all the way up until the retainer latch locks the cage in place on
the chassis.
v Non-hot-swap models, lift up the power-supply cage handle and pull the
power-supply cage assembly all the way up until the retainer latch locks the
cage in place on the chassis.
to release the front system fan cage assembly from the connector on the
chassis.
instructions, and use any packaging materials for shipping that are supplied to
you.
Fan cage assembly
release buttons
Fan cage assembly

Advertisement