Easy LED Diagnostics panel (TD100x only)
To remove the Easy LED Diagnostics panel, complete the following steps.
Light path
diagnostics panel
1. Read the safety information that begins on page vii and "Safety statements" on
2. Turn off the server and peripheral devices, and disconnect the power cords and
3. Unlock and remove the left-side cover (see "Removing the side cover" on page
4. Disconnect the Easy LED Diagnostics panel cable from the system board.
5. Press in on the release tab and twist the Easy LED Diagnostics panel clockwise
To install a replacement Easy LED Diagnostics panel, complete the following steps:
1. While you hold the cable out of the way, position the Easy LED Diagnostics
2. Rotate the panel counter clockwise until it clicks into place.
3. Connect the cable to the system board.
4. Install the left-side cover and close the bezel.
5. Reconnect power cords and external cables.
146
ThinkServer TD100 and TD100x: Hardware Maintenance Manual
page x.
all external cable as necessary to replace the device.
78).
until it stops; then, remove the panel from the server.
panel over the slots on the side of the drive bay cage.
Release Tab