Lenovo ThinkServer TD100 Hardware Maintenance Manual page 218

Types 6398, 6399, 6419, 6429, 4203, 4204, 4205, and 4206
Hide thumbs Also See for ThinkServer TD100:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206," on page 25 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
201-xxx-n99
Failed memory test.
Note: n = 1-4 (DIMM pair)
99 = Both DIMMs in the pair failed
202-xxx-00n
Failed system cache test.
215-xxx-000
Failed CD or DVD test.
217-xxx-000
Failed fixed disk test.
Note: If RAID is configured, the fixed disk
number refers to the RAID logical array.
217-xxx-001
Failed fixed disk test.
Note: If RAID is configured, the fixed disk
number refers to the RAID logical array.
217-xxx-002
Failed fixed disk test.
Note: If RAID is configured, the fixed disk
number refers to the RAID logical array.
217-xxx-003
Failed fixed disk test.
Note: If RAID is configured, the fixed disk
number refers to the RAID logical array.
200
ThinkServer TD100 and TD100x: Hardware Maintenance Manual
Action
1. Reseat the DIMMs.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. DIMM pair
b. (Trained service technician only) System
board
1. (Trained service technician only) Reseat
microprocessor n.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. (Trained service technician only)
Microprocessor n
b. (Trained service technician only) System
board
1. Run the test again with a different CD or DVD.
2. Reseat the CD or DVD drive cable.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. CD or DVD drive
b. (Trained service technician only) System
board
1. Reseat hard disk drive 1.
2. Replace hard disk drive 1.
1. Reseat hard disk drive 2.
2. Replace hard disk drive 2.
1. Reseat hard disk drive 3.
2. Replace hard disk drive 3.
1. Reseat hard disk drive 4.
2. Replace hard disk drive 4.

Advertisement