Installing the front system fan cage assembly

Attention:
v Replace a failed fan within 48 hours.
v To ensure proper cooling and airflow, do not operate the server for more than 30
To install the front system fan cage assembly, complete the following steps.
1. Align the front system fan cage assembly 1 over the fan cage assembly slot
2. Lower the fan cage assembly into the chassis and press down firmly until the
3. Press the power-supply cage release tab and rotate the power-supply cage
4. Return the power-supply cage handle to the locked position.
5. If you have a hot-swap model, reinstall the hot-swap power supplies (see
6. Install the side cover (see "Installing the side cover" on page 79).
7. Lock the side cover.
8. Reconnect the external cables and power cords; then, turn on the attached
minutes with the side cover removed.
and with the connector on the system board.
fan cage assembly is seated firmly in place.
assembly into the chassis until it locks in place.
"Installing a hot-swap power supply" on page 96).
devices and turn on the server.
Chapter 4. Removing and replacing server components
109