Installing The Control-Panel Assembly - Lenovo ThinkServer TD100 Hardware Maintenance Manual

Types 6398, 6399, 6419, 6429, 4203, 4204, 4205, and 4206
Hide thumbs Also See for ThinkServer TD100:
Table of Contents

Advertisement

Installing the control-panel assembly

To install the control-panel assembly, complete the following steps.
10. Install the side cover (see "Installing the side cover" on page 79).
11. Lock the side cover.
12. Reconnect the external cables and power cords; then, turn on the attached
124
ThinkServer TD100 and TD100x: Hardware Maintenance Manual
1. Position the front end of the control-panel assembly in the channel above drive
bay 1.
2. Slide the control-panel assembly toward the front of the chassis until it clicks
into place.
3. Reroute and connect the control-panel assembly cable to the system board
(see "System-board internal connectors" on page 10 for the location of the
front panel connector).
4. Slide the drives in bay 1 and bay 2 back into the drive bays if you pushed
them slightly out earlier (see "Installing a CD or DVD drive" on page 87 for
more information).
5. Reinstall the front fan cage assembly (see "Installing the front system fan cage
assembly" on page 109.
6. Press the power-supply cage release tab and rotate the power-supply cage
assembly into the chassis until it locks in place.
7. Return the power-supply cage handle to the locked position.
8. If you have a hot-swap model, reinstall the hot-swap power supplies (see
"Installing a hot-swap power supply" on page 96).
9. Replace the bezel (see "Replacing the bezel" on page 77).
devices and turn on the server.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinkserver td100x

Table of Contents