Lenovo ThinkServer TD100 Hardware Maintenance Manual page 210

Types 6398, 6399, 6419, 6429, 4203, 4204, 4205, and 4206
Hide thumbs Also See for ThinkServer TD100:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206," on page 25 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
001-292-000
Core system: failed/CMOS checksum failed. Load the BIOS default settings by using the
005-xxx-000
Failed video test.
011-xxx-000
Failed COM1 serial port test.
015-xxx-001
Failed USB test.
015-xxx-198
Remote Supervisor Adapter II SlimLine
installed or USB device connected during
USB test.
020-xxx-000
Failed PCI Interface test.
030-265-001
Communication Error.
030-266-001
A SAS/SATA Channel Error.
192
ThinkServer TD100 and TD100x: Hardware Maintenance Manual
Action
Configuration/Setup Utility program, and run the test
again (see "Using the Configuration/Setup Utility
program" on page 16).
1. Reseat the video adapter, if one is installed.
2. (Trained service technician only) Replace the
system board.
1. Check the loopback plug that is connected to the
externalized serial port.
2. Check the cable from the externalized serial port
to the system board.
3. (Trained service technician only) Replace the
system board.
(Trained service technician only) Replace the system
board.
1. If a Remote Supervisor Adapter II SlimLine is
installed as an option, remove it and run the test
again.
2. Remove all USB devices and run the test again.
3. (Trained service technician only) Replace the
system board.
1. Reseat the PCI, PCI-X, or PCI Express adapter.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Adapter
b. (Trained service technician only) System
board
1. Update the microcode for the Serial Attached
SCSI (SAS)/SATA controller (see "Updating the
firmware" on page 15).
2. Update the BIOS code (see "Updating the
firmware" on page 15).
3. (Trained service technician only) Replace the
system board.
1. Update the microcode for the onboard Serial
Attached SCSI (SAS)/SATA controller (see
"Updating the firmware" on page 15).
2. Update the BIOS code (see "Updating the
firmware" on page 15).
3. (Trained service technician only) Replace the
system board.