7 .
Open the peripherals box and remove the USB cable (A), country specific
power cord (B), print platform (C), curing bulb (D), power supply (E) and
material cartridge (F) .
NOTE: Keep the material cartridge away from direct light . UV light
will begin to cure the print resin in the cartridge and render it
useless .
8 .
Open the print door and remove the plastic insert (A) from the material
cartridge support .
NOTE: If necessary, lift the print material cartridge clamp lever (B)
to gain more clearance .
NOTE: When installing the UV curing bulb, ensure the plastic insert
is reinserted in the material cartridge clamp . The plastic insert
is designed to protect the glass pane in the material cartridge
support .