Camera System Adjustments - Sony HVR-A1J Service Manual

Digital hd video camera recorder
Table of Contents

Advertisement

1-3.

CAMERA SYSTEM ADJUSTMENTS

Before perform the camera system adjustments, check that the
specified values of "VIDEO SYSTEM ADJUSTMENTS" are sat-
isfied. (Except Origin Oscillation Check")
Check that the data of page: 0, address: 10 is "00".
If not, select page: 0, address: 10, and set the data "00".
1. Origin Oscillation Check (TT-001 board)
Check the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color
will become inconsistent.
Subject
Not required
Measurement Point
Pin 5 of IC1403 on TT-001 board
Measuring Instrument
Frequency counter
f = 44505000 ± 895 Hz (NTSC)
Specified value
f = 37125000 ± 745 Hz (PAL)
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Checking method:
1) Check that the frequency (f) satisfies the specified value.
TT-001 BOARD (SIDE A)
8
5
1
4
Fig. 6-1-6
HVR-A1J/A1U/A1N/A1E/A1P/A1C
IC1403
6-28