25. White Defect Adjustment
Defect white defective pixels of CMOS image sensor.
Subject
Not required
Measurement Point
Adjusting remote commander
Measuring Instrument
Specified value
Data of page: 6 address: D3 is "00"
Note 1: Perform "Auto White Balance Adjustment" before this
adjustment.
Note 2: Check that the data of page: 0, address: 10 is "00".
Note 3: Check that the data of page: 6, address: 02 is "00".
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
1
0
01
01
2
6
0D
3
0
10
06
B
4
41
10
(6B)
5
0
10
00
6
6
D0
06
7
6
01
21
8
6
02
9
6
D3
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
00
2
0
10
06
B
3
41
10
(6B)
4
0
10
00
5
0
01
00
HVR-A1J/A1U/A1N/A1E/A1P/A1C
RadarW
RadarW
RadarW
RadarW
RadarW
Procedure
Check the data is "04".
Press PAUSE (Write) button.
Press PAUSE (Write) button.
Check the data changes to
"01".
Check the data is "00".
Procedure
Press PAUSE (Write) button.
Press PAUSE (Write) button.
26. White Defect Adjustment (FD white point)
RadarW
RadarW
RadarW
RadarW
RadarW
Defect white defective pixels (FD white point) of CMOS image
sensor.
Subject
Note 1: Perform "White Defect Adjustment" before this adjust-
ment.
Note 2: Check that the data of page: 0, address: 10 is "00".
Note 3: Check that the data of page: 6, address: 02 is "00".
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
1
0
01
2
6
0D
3
0
10
B
4
41
(6B)
5
0
10
6
6
D0
7
6
01
8
6
02
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
0
10
B
3
41
(6B)
4
0
10
5
0
01
6-54
Not required
Procedure
01
Check the data is "04".
06
02
Press PAUSE (Write) button.
00
0C
21
Press PAUSE (Write) button.
Check the data changes to
"01".
Procedure
00
Press PAUSE (Write) button.
06
10
Press PAUSE (Write) button.
00
00