3-24.
GL Gear (T)
1. Removal procedure
1)
Remove the GL arm claw 1 in the direction of the arrow.
2)
Remove the GL arm (T) ass'y 2.
3)
Remove the GL torsion coil spring (T) 3 from the GL gear
(T) 4.
2 GL arm (T) ass'y
3 Torsion coil spring (T)
4 GL gear (T)
HVR-A1J/A1U/A1N/A1E/A1P/A1C
2. Attachment procedure
1)
Install the torsion coil spring (T) 2 in the GL gear (T) 1.
2)
Engage the GL arm (T) claw 3 in the A portion of the torsion
coil spring (T).
3)
Engage the GL arm (T) claw in the groove of the GL gear (T)
by rotating the GL arm (T) ass'y in the direction of the arrow
B.
2 Torsion coil spring (T)
1 GL arm claw
1 GL gear (T)
GL arm (T) ass'y
Groove of the GL gear (T)
6-95
3 GL arm claw
A
4 Torsion coil spring (T)
B
Torsion coil spring (T)
GL arm claw
Torsion coil spring (T)