21. PCGM Standard Data Input
Adjust the matrix coefficient for compensating the variation in
spectral sensitivity, to carry out presumed detection of the light
source for AWB.
Adjustment Page
Adjustment Address
Note 1: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to "00".
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 06.
3) Input the following data to page: 6F, address: 2E to 3F.
Note 2: Press the PAUSE (Write) button of the adjustment remote
commander each time to set data.
Address
NTSC PAL
2E
1F
2F
64
30
FF
31
3E
32
00
33
23
34
01
35
CF
36
1E
37
1B
38
00
39
F9
3A
00
3B
84
3C
FF
3D
A4
3E
1F
3F
8B
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
HVR-A1J/A1U/A1N/A1E/A1P/A1C
RadarW
RadarW
RadarW
6F
2E to 3F
Data
1F
64
FF
3E
00
23
01
CF
1E
1B
00
F9
00
84
FF
A4
1F
8B