Reported Event
Blowers are functioning
normally
Blowers are NOT installed Reinstall the fan. If the fan does not turn, replace it.
Blower status is unknown Check for airflow out of the cooling unit. If there is
Cache
BBU flushing has started VessRAID's cache is being flushed.
BBU flushing has ended
BBU flushing has failed
Controller
The controller
parameter(s) changed by
user
The controller has new
crash information
Controller temperature is
above the threshold/
warning threshold
Controller temperature is
above the critical
threshold
Disk Array
New disk array has been
created
Disk array has been
deleted
Disk array has been
added
Disk array has been
removed
Disk array settings have
been changed
Normal.
See page 210.
none, check for proper installation.
VessRAID's cache has been flushed.
VessRAID's cache could not be flushed. Check your
cache flush interval setting. See page 83 (WebPAM
PROe) or page 129 (CLU).
The user successfully changed controller settings.
See page 83 (WebPAM PROe) or page 129 (CLU).
Check the event logs. See page 49 and 50 (WebPAM
PROe) or page 162 (CLU)
The VessRAID controller is overheating. Check for
airflow around and through the controller, and verify
that all fans are working. Replace fans as needed.
The VessRAID controller is seriously overheating.
Check for airflow around and through the controller,
and verify that all fans are working. Replace fans as
needed.
Result of settings or user action. Normal.
Result of settings or user action. Normal.
Result of settings or user action. Normal.
The physical drives of the disk array were removed
from the enclosure.
The user successfully disk array settings. See
page 104 (WebPAM PROe) or page 145 (CLU).
265
Chapter 9: Troubleshooting
Corrective Action