Calling Up The Error Code - Winterhalter UC Series Operating Instructions Manual

Dishwashing machines winterhalter uc-s/ uc-m/ uc-l/ uc-xl
Hide thumbs Also See for UC Series:
Table of Contents

Advertisement

Malfunctions
Pictogram Meaning
flashing
Inbuilt partial
alternately
demineraliser exhausted
with
Chip was not recognised
The service interval has
expired
Check scaling
The bottom wash field is
blocked
The top wash field is
blocked
Foaming
The strainer is blocked
Energy optimisation
Malfunction with error
code

15.2 Calling up the error code

1
is only displayed if the machine is connected to an energy optimisation system.
30
Possible cause
Low regeneration agent
Chip already validated or
defective
The number of operating hours
entered on the control unit has
elapsed. The machine should be
serviced.
INFO: This function is not
activated in factory.
The number of operating hours
entered on the control unit has
elapsed. The machine should be
descaled.
The lower wash field is blocked,
e.g. by a piece of cutlery
The top wash field is blocked,
e.g. by tall dishes
Use of manual wash-up cleaner
Large amount of protein
Heavily soiled strainer
The on-site energy optimisation
system switches individual
1
electrical loads (heating elements)
off.
Various
The
 Press the button "i
 Screen 33 appears
Remedy
Fill the reservoir with
DeMatik Pi-240 Reg
regeneration agent and unlock
the electronics (see  8.4 and
8.5)
Hold the cap of a new bottle of
regeneration agent against the
reader (see  8.5).
Contact a Winterhalter
authorised service technician of
the pictogram does not
disappear.
Call a service technician
authorised by Winterhalter
Start the descaling programme
(see  16.6.1)
Switch to info level 2 to delete
the pictogram in the info field
without starting the descaling
programme
Remove the blockage
Remove the blockage
Drain and re-fill the machine
Remove, clean and replace the
strainer
Wait until the on-site energy
optimisation system switches
off
Call up the error code
(see  15.2) and call a service
technician authorised by
Winterhalter
symbol in the info field (4) flashes.
" and then the button "i