Gas Supply Requirements; Gas Connection - Waldorf 800 Series RN8910GE Installation And Operation Manual

Gas range electric static/convection oven
Table of Contents

Advertisement

Specifications

Gas Supply Requirements

- Australia:
Input Rate (N.H.G.C.)
- each Open Burner
Supply Pressure
Burner Operating Pressure (*)

Gas Connection

- New Zealand:
Input Rate (N.H.G.C.)
- each Open Burner
Supply Pressure
Burner Operating Pressure (*)
Gas Connection
- UK Only:
Category:
Flue Type:
Heat Input (nett)
Gas Rate (nett)
Supply Pressure
Burner Operating Pressure (*)
Gas Connection
*
Measure burner operating pressure at manifold test point with two burners operating at full
setting. Operating pressure is ex-factory set through the appliance regulator and is not to be
adjusted, apart from when carrying out gas conversion, if required.
Conversion' section for details).
Natural Gas
1.13 - 3.40 kPa
Natural Gas
1.13 - 3.40 kPa
II
(20, 37).
2H3P
A
1.
Natural Gas (G20)
Open Burner (each)
Nominal
Reduced
Nominal
Reduced
4
LP Gas (Propane)
28 MJ/hr
0.95 kPa
3
/
" B.S.P. Male
4
28 MJ/hr
0.95 kPa
3
/
" B.S.P. Male
4
6.5 kW
1.75 kW
3
0.69 m
/hr
3
0.19 m
/hr
20 mbar
9.5 mbar
3
/
" B.S.P. Male
4
28 MJ/hr
2.75 - 4.50 kPa
2.6 kPa
LP Gas
28 MJ/hr
2.75 - 4.50 kPa
2.6 kPa
Propane (G31)
Open Burner (each)
6.5 kW
1.75 kW
0.51 kg/hr
0.14 kg/hr
37 mbar
26 mbar
(Refer to 'Gas